Cooling system at the compressors air inlet of the gas turbines from the Tula`s combined cycle central; Sistema de enfriamiento en la succion del compresor de las turbinas de gas de la central de ciclo combinado de Tula

Abstract

It has been formerly evaluated that it is possible to enhance notably the electric power generation in gas turbine power plants by cooling the air at the compressor inlet. It has been pointed out that provided a source of waste heat is available it can be very attractive the use of absorption refrigeration systems. In this paper the technical and the economical benefits of bringing the air inlet temperature down 8 Celsius degrees of the four gas turbines of the Combined Cycle Central of Tula, in the State of Hidalgo (combined cycle central-Tula) are evaluated. The results show that it is possible to achieve an efficiency enhancement of at least 1%, and that in very warm days up to 48 additional Megawatts can be generated, or about 10% of the installed capacity. The final economic result is very encouraging and an annual economical benefit in the order of 50 million pesos can be obtained and the refrigeration units can be amortized in approximately one year. [Espanol] Se ha evaluado anteriormente que es posible mejorar notablemente la capacidad de generacion electrica en plantas que utilizan turbinas de gas, mediante el enfriamiento del aire de succion del compresor. Se ha senalado que  More>>
Authors:
Gonzalez F, Oscar; [1]  Romero Paredes, Hernando; Vargas, Martin; Gomez, Jose Francisco [2] 
  1. Comision Federal de Electricidad, Tula (Mexico)
  2. Universidad Autonoma Metropolitana-Iztapalapa, Mexico, D. F. (Mexico)
Publication Date:
Dec 31, 1996
Product Type:
Miscellaneous
Report Number:
CONF-9611244-
Reference Number:
SCA: 200100; PA: MX-98:000046; EDB-99:040658; SN: 98002000310
Resource Relation:
Conference: 17. national seminar on the rational use of the energy and exposition of equipment and services, 17. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, Mexico (Mexico), 25-29 Nov 1996; Other Information: PBD: 1996; Related Information: Is Part Of 17. national seminar on the rational use of the energy and exposition of equipment and services. Transactions; PB: 722 p.; 17. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria tecnica
Subject:
20 FOSSIL-FUELED POWER PLANTS; COOLING SYSTEMS; COMBINED-CYCLE POWER PLANTS; GAS TURBINE POWER PLANTS; NUMERICAL DATA; TULA; HIDALGO
OSTI ID:
331561
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE99717744; TRN: MX9800046
Availability:
Available from Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), Av. Revolucion 728, Oficina 15, Col. Nonoalco Mixcoac, C.P. 03700, Mexico D. F. (Mexico), Tel./Fax: (5) 611 9280; OSTI as DE99717744
Submitting Site:
MX
Size:
pp. 207-216
Announcement Date:
Apr 28, 1999

Citation Formats

Gonzalez F, Oscar, Romero Paredes, Hernando, Vargas, Martin, and Gomez, Jose Francisco. Cooling system at the compressors air inlet of the gas turbines from the Tula`s combined cycle central; Sistema de enfriamiento en la succion del compresor de las turbinas de gas de la central de ciclo combinado de Tula. Mexico: N. p., 1996. Web.
Gonzalez F, Oscar, Romero Paredes, Hernando, Vargas, Martin, & Gomez, Jose Francisco. Cooling system at the compressors air inlet of the gas turbines from the Tula`s combined cycle central; Sistema de enfriamiento en la succion del compresor de las turbinas de gas de la central de ciclo combinado de Tula. Mexico.
Gonzalez F, Oscar, Romero Paredes, Hernando, Vargas, Martin, and Gomez, Jose Francisco. 1996. "Cooling system at the compressors air inlet of the gas turbines from the Tula`s combined cycle central; Sistema de enfriamiento en la succion del compresor de las turbinas de gas de la central de ciclo combinado de Tula." Mexico.
@misc{etde_331561,
title = {Cooling system at the compressors air inlet of the gas turbines from the Tula`s combined cycle central; Sistema de enfriamiento en la succion del compresor de las turbinas de gas de la central de ciclo combinado de Tula}
author = {Gonzalez F, Oscar, Romero Paredes, Hernando, Vargas, Martin, and Gomez, Jose Francisco}
abstractNote = {It has been formerly evaluated that it is possible to enhance notably the electric power generation in gas turbine power plants by cooling the air at the compressor inlet. It has been pointed out that provided a source of waste heat is available it can be very attractive the use of absorption refrigeration systems. In this paper the technical and the economical benefits of bringing the air inlet temperature down 8 Celsius degrees of the four gas turbines of the Combined Cycle Central of Tula, in the State of Hidalgo (combined cycle central-Tula) are evaluated. The results show that it is possible to achieve an efficiency enhancement of at least 1%, and that in very warm days up to 48 additional Megawatts can be generated, or about 10% of the installed capacity. The final economic result is very encouraging and an annual economical benefit in the order of 50 million pesos can be obtained and the refrigeration units can be amortized in approximately one year. [Espanol] Se ha evaluado anteriormente que es posible mejorar notablemente la capacidad de generacion electrica en plantas que utilizan turbinas de gas, mediante el enfriamiento del aire de succion del compresor. Se ha senalado que en la medida en que se encuentre disponible una fuente termica de desecho puede ser muy atractivo el uso de sistemas de refrigeracion por absorcion. En el presente trabajo se evaluan los beneficios tecnicos y economicos que puede tener el llevar el aire de succion hasta una temperatura de 8 grados Celsius, de las cuatro unidades de gas de la Central de Ciclo Combinado de Tula, Hidalgo (CCC-Tula). Los resultados muestran que es posible alcanzar un aumento en la eficiencia de al menos 1% y que se pueden generar, en dias muy calurosos, hasta 48 MW extras, equivalente al 10% de la capacidad instalada. El resultado economico final es muy alentador y puede llegar a tenerse un beneficio economico del orden de los 50 millones de pesos anuales y las unidades de refrigeracion podran pagarse en aproximadamente un ano.}
place = {Mexico}
year = {1996}
month = {Dec}
}