Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica

Abstract

In a lighting system the discharge lamps (fluorescent and high intensity discharge (HID)), ballast and controls are generating elements of harmonics. As a consequence of the tendency of saving energy, the use of electronic ballasts and controls that integrate dimmers, daylight and present sensors has increased in order to optimize the energy use. This paper presents the harmonics generation resulting from the fluorescent lamps operating different electronic ballasts as well as their electronic controls. Likewise, are also shown the effects caused by generation of harmonics components by the lighting system in the electric system that go from the voltage and current distortion, the presence of currents in the neutral conductor in balanced systems to the repercussions in the metering equipment such as watthour meters and the effects the lighting equipment suffer due to the presence of harmonics, such as the power factor decrease in ballasts that are of high power factor and the temperature increment in the magnetic type ballasts. [Espanol] Dentro de un sistema de iluminacion, las lamparas de descarga (fluorescentes y alta intensidad de descarga {sup H}ID{sup )}, balastros y los controles son elementos generadores de armonicas. A consecuencia de la tendencia al ahorro de energia se ha  More>>
Authors:
Garibay Mendoza, V; [1]  Hernandez Bernal, J M [2] 
  1. Lumisistemas, departamento de aseguramineto de calidad, Naucalpan (Mexico)
  2. UNICORP, Mexico, D. F. (Mexico)
Publication Date:
Dec 31, 1995
Product Type:
Miscellaneous
Report Number:
CONF-9511314-
Reference Number:
SCA: 320106; PA: MX-98:000036; EDB-99:041430; SN: 98001999975
Resource Relation:
Conference: 16. national seminar on the rational use of the energy and exposition of equipment and services, 16. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, Mexico (Mexico), 27 Nov - 1 Dec 1995; Other Information: PBD: 1995; Related Information: Is Part Of 16. national seminar on the rational use of the energy and exposition of equipment and services. Transactions; PB: 736 p.; 16. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria tecnica
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; HARMONICS; FLUORESCENT LAMPS; LIGHTING SYSTEMS; NUMERICAL DATA
OSTI ID:
331542
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE99717745; TRN: MX9800036
Availability:
Also available from Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), Av. Revolucion 728, Oficina 15, Col. Nonoalco Mixcoac, C.P. 03700, Mexico D. F. (Mexico), Tel./Fax: (5) 611 9280; OSTI as DE99717745
Submitting Site:
MX
Size:
pp. 459-468
Announcement Date:
Apr 28, 1999

Citation Formats

Garibay Mendoza, V, and Hernandez Bernal, J M. Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica. Mexico: N. p., 1995. Web.
Garibay Mendoza, V, & Hernandez Bernal, J M. Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica. Mexico.
Garibay Mendoza, V, and Hernandez Bernal, J M. 1995. "Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica." Mexico.
@misc{etde_331542,
title = {Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica}
author = {Garibay Mendoza, V, and Hernandez Bernal, J M}
abstractNote = {In a lighting system the discharge lamps (fluorescent and high intensity discharge (HID)), ballast and controls are generating elements of harmonics. As a consequence of the tendency of saving energy, the use of electronic ballasts and controls that integrate dimmers, daylight and present sensors has increased in order to optimize the energy use. This paper presents the harmonics generation resulting from the fluorescent lamps operating different electronic ballasts as well as their electronic controls. Likewise, are also shown the effects caused by generation of harmonics components by the lighting system in the electric system that go from the voltage and current distortion, the presence of currents in the neutral conductor in balanced systems to the repercussions in the metering equipment such as watthour meters and the effects the lighting equipment suffer due to the presence of harmonics, such as the power factor decrease in ballasts that are of high power factor and the temperature increment in the magnetic type ballasts. [Espanol] Dentro de un sistema de iluminacion, las lamparas de descarga (fluorescentes y alta intensidad de descarga {sup H}ID{sup )}, balastros y los controles son elementos generadores de armonicas. A consecuencia de la tendencia al ahorro de energia se ha incrementado el uso de balastros electronicos y controles que integran atenuadores de luz (dimmers), sensores de luz natural y de presencia con el fin de optimizar el uso de la energia. Este trabajo presenta los resultados de generacion de armonicas para lamparas fluorescentes, operando diferentes balastros electronicos asi como con controles electronicos. Asi mismo son presentados los efectos causados por la generacion de componentes armonicas por el sistema de iluminacion dentro del sistema electrico que van desde la distorsion en voltaje y corriente, la presencia de corrientes dentro del conductor neutro en sistemas balanceados, asi como la repercusion en los equipos de medicion tales como los watthorimetros y los efectos que sufren los equipos de iluminacion debido a la presencia de armonicas tales como la disminucion del factor de potencia en balastros que son de alto factor de potencia y el incremento de la temperatura de operacion de balastros del tipo magnetico.}
place = {Mexico}
year = {1995}
month = {Dec}
}