You need JavaScript to view this

Temperature and pressure control in the discharge of refrigeration systems cooled by shell and tube condensers; Control de presion y temperatura de descarga en sistemas de refrigeracion enfriados por condensadores de casco y tubo

Abstract

In the selection of a refrigeration equipment, the evaporator and condenser load conditions must be perfectly known, that is, the amount of heat energy that we have to reject from our space to cool in base to the temperature and mass to refrigerate. This situation carries on to the selection of the adequate compressor. But nevertheless the temperature conditions of the environment play an important roll in the behavior of the entire refrigeration system, altering in many cases the working conditions of each one of the components and therefore the functioning of the refrigeration system. This paper presents a method for controlling the behavior of each one of the components of the refrigeration system that perform in accordance with their design characteristics. [Espanol] En la seleccion de un equipo de refrigeracion, se deben conocer perfectamente las condiciones de carga del evaporador y del condensador, es decir la cantidad de calor que debemos de eliminar de nuestro medio a refrigerar, en base a la temperatura y masa a refrigerar. Esta situacion conlleva a la eleccion del compresor adecuado. Mas sin embargo, las condiciones de temperatura ambiente, juegan un papel importante en el comportamiento de todo el sistema de refrigeracion, alterando en  More>>
Authors:
Fernandez Martinez, R [1] 
  1. Asociacion de Ingenieros Egresados de la Universidad Autonoma Metropolitana, Mexico D. F. (Mexico)
Publication Date:
Dec 31, 1995
Product Type:
Miscellaneous
Report Number:
CONF-9511314-
Reference Number:
SCA: 320106; PA: MX-98:000032; EDB-99:041421; SN: 98001999971
Resource Relation:
Conference: 16. national seminar on the rational use of the energy and exposition of equipment and services, 16. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, Mexico (Mexico), 27 Nov - 1 Dec 1995; Other Information: PBD: 1995; Related Information: Is Part Of 16. national seminar on the rational use of the energy and exposition of equipment and services. Transactions; PB: 736 p.; 16. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria tecnica
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; REFRIGERATION; COMPRESSORS; NUMERICAL DATA
OSTI ID:
331538
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE99717745; TRN: MX9800032
Availability:
Also available from Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), Av. Revolucion 728, Oficina 15, Col. Nonoalco Mixcoac, C.P. 03700, Mexico D. F. (Mexico), Tel./Fax: (5) 611 9280; OSTI as DE99717745
Submitting Site:
MX
Size:
pp. 407-414
Announcement Date:

Citation Formats

Fernandez Martinez, R. Temperature and pressure control in the discharge of refrigeration systems cooled by shell and tube condensers; Control de presion y temperatura de descarga en sistemas de refrigeracion enfriados por condensadores de casco y tubo. Mexico: N. p., 1995. Web.
Fernandez Martinez, R. Temperature and pressure control in the discharge of refrigeration systems cooled by shell and tube condensers; Control de presion y temperatura de descarga en sistemas de refrigeracion enfriados por condensadores de casco y tubo. Mexico.
Fernandez Martinez, R. 1995. "Temperature and pressure control in the discharge of refrigeration systems cooled by shell and tube condensers; Control de presion y temperatura de descarga en sistemas de refrigeracion enfriados por condensadores de casco y tubo." Mexico.
@misc{etde_331538,
title = {Temperature and pressure control in the discharge of refrigeration systems cooled by shell and tube condensers; Control de presion y temperatura de descarga en sistemas de refrigeracion enfriados por condensadores de casco y tubo}
author = {Fernandez Martinez, R}
abstractNote = {In the selection of a refrigeration equipment, the evaporator and condenser load conditions must be perfectly known, that is, the amount of heat energy that we have to reject from our space to cool in base to the temperature and mass to refrigerate. This situation carries on to the selection of the adequate compressor. But nevertheless the temperature conditions of the environment play an important roll in the behavior of the entire refrigeration system, altering in many cases the working conditions of each one of the components and therefore the functioning of the refrigeration system. This paper presents a method for controlling the behavior of each one of the components of the refrigeration system that perform in accordance with their design characteristics. [Espanol] En la seleccion de un equipo de refrigeracion, se deben conocer perfectamente las condiciones de carga del evaporador y del condensador, es decir la cantidad de calor que debemos de eliminar de nuestro medio a refrigerar, en base a la temperatura y masa a refrigerar. Esta situacion conlleva a la eleccion del compresor adecuado. Mas sin embargo, las condiciones de temperatura ambiente, juegan un papel importante en el comportamiento de todo el sistema de refrigeracion, alterando en muchos casos las condiciones de trabajo de cada uno de los componentes y por ende el funcionamiento del sistema de refrigeracion. El presente trabajo presenta un metodo para controlar el comportamiento de cada uno de los componentes dentro del sistema de refrigeracion para que trabajen de acuerdo a su diseno.}
place = {Mexico}
year = {1995}
month = {Dec}
}