Determination of optimum pressurizer level for kori unit 1

Abstract

To determine the optimum pressurizer water level during normal operation for Kori unit 1, performance and safety analysis are performed. The methodology is developed by evaluating {sup d}ecrease in secondary heat removal{sup e}vents such as Loss of Normal Feedwater accident. To demonstrate optimum pressurizer level setpoint, RETRAN-03 code is used for performance analysis. Analysis results of RETRAN following reactor trip are compared with the actual plant data to justify RETRAN code modelling. The results of performance and safety analyses show that the newly established level setpoints not only improve the performance of pressurizer during transient including reactor trip but also meet the design bases of the pressurizer volume and pressure. 6 refs., 5 figs. (Author)
Authors:
Song, Dong Soo; Lee, Chang Sup; Yong, Lee Jae; Kim, Yo Han; Lee, Dong Hyuk [1] 
  1. Korea Electric Power Research Institute, Taejon (Korea, Republic of)
Publication Date:
Dec 31, 1997
Product Type:
Conference
Report Number:
ETDE/KR-99732628; CONF-9710296-
Reference Number:
SCA: 210200; 220200; 220400; PA: KR-99:000299; EDB-99:035045; SN: 99002059926
Resource Relation:
Conference: Korean Nuclear Society autumn meeting, Taegu (Korea, Republic of), 24-25 Oct 1997; Other Information: PBD: 1997; Related Information: Is Part Of Proceedings of the korean nuclear society autumn meeting vol I, October 24-25, 1997 Taegu, Korea; PB: 797 p.
Subject:
21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS; 22 NUCLEAR REACTOR TECHNOLOGY; PRESSURIZERS; REACTOR COOLING SYSTEMS; FEEDWATER; LOSS OF COOLANT; WATER SUPPLY; KORI-1 REACTOR; LEVELS; SAFETY; TRANSIENTS; OPTIMIZATION; CONTROL SYSTEMS
OSTI ID:
324134
Research Organizations:
Korean Nuclear Society, Taejon (Korea, Republic of)
Country of Origin:
Korea, Republic of
Language:
English
Other Identifying Numbers:
Other: ON: DE99732628; TRN: KR9900299
Availability:
OSTI as DE99732628
Submitting Site:
KR
Size:
pp. 437-442
Announcement Date:
Apr 01, 1999

Citation Formats

Song, Dong Soo, Lee, Chang Sup, Yong, Lee Jae, Kim, Yo Han, and Lee, Dong Hyuk. Determination of optimum pressurizer level for kori unit 1. Korea, Republic of: N. p., 1997. Web.
Song, Dong Soo, Lee, Chang Sup, Yong, Lee Jae, Kim, Yo Han, & Lee, Dong Hyuk. Determination of optimum pressurizer level for kori unit 1. Korea, Republic of.
Song, Dong Soo, Lee, Chang Sup, Yong, Lee Jae, Kim, Yo Han, and Lee, Dong Hyuk. 1997. "Determination of optimum pressurizer level for kori unit 1." Korea, Republic of.
@misc{etde_324134,
title = {Determination of optimum pressurizer level for kori unit 1}
author = {Song, Dong Soo, Lee, Chang Sup, Yong, Lee Jae, Kim, Yo Han, and Lee, Dong Hyuk}
abstractNote = {To determine the optimum pressurizer water level during normal operation for Kori unit 1, performance and safety analysis are performed. The methodology is developed by evaluating {sup d}ecrease in secondary heat removal{sup e}vents such as Loss of Normal Feedwater accident. To demonstrate optimum pressurizer level setpoint, RETRAN-03 code is used for performance analysis. Analysis results of RETRAN following reactor trip are compared with the actual plant data to justify RETRAN code modelling. The results of performance and safety analyses show that the newly established level setpoints not only improve the performance of pressurizer during transient including reactor trip but also meet the design bases of the pressurizer volume and pressure. 6 refs., 5 figs. (Author)}
place = {Korea, Republic of}
year = {1997}
month = {Dec}
}