Maximum entropy algorithm and its implementation for the neutral beam profile measurement

Abstract

A tomography algorithm to maximize the entropy of image using Lagrangian multiplier technique and conjugate gradient method has been designed for the measurement of 2D spatial distribution of intense neutral beams of KSTAR NBI (Korea Superconducting Tokamak Advanced Research Neutral Beam Injector), which is now being designed. A possible detection system was assumed and a numerical simulation has been implemented to test the reconstruction quality of given beam profiles. This algorithm has the good applicability for sparse projection data and thus, can be used for the neutral beam tomography. 8 refs., 3 figs. (Author)
Authors:
Lee, Seung Wook; Cho, Gyu Seong; [1]  Cho, Yong Sub [2] 
  1. Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)
  2. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
Publication Date:
Dec 31, 1997
Product Type:
Conference
Report Number:
ETDE/KR-99732628; CONF-9710296-
Reference Number:
SCA: 430000; 661220; PA: KR-99:000296; EDB-99:037487; SN: 99002059923
Resource Relation:
Conference: Korean Nuclear Society autumn meeting, Taegu (Korea, Republic of), 24-25 Oct 1997; Other Information: PBD: 1997; Related Information: Is Part Of Proceedings of the korean nuclear society autumn meeting vol I, October 24-25, 1997 Taegu, Korea; PB: 797 p.
Subject:
43 PARTICLE ACCELERATORS; 66 PHYSICS; ENTROPY; ALGORITHMS; NEUTRAL BEAM SOURCES; BEAM PROFILES; TOMOGRAPHY; LAGRANGIAN FUNCTION; SPATIAL DISTRIBUTION; NEUTRAL ATOM BEAM INJECTION
OSTI ID:
324124
Research Organizations:
Korean Nuclear Society, Taejon (Korea, Republic of)
Country of Origin:
Korea, Republic of
Language:
English
Other Identifying Numbers:
Other: ON: DE99732628; TRN: KR9900296
Availability:
OSTI as DE99732628
Submitting Site:
KR
Size:
pp. 329-334
Announcement Date:

Citation Formats

Lee, Seung Wook, Cho, Gyu Seong, and Cho, Yong Sub. Maximum entropy algorithm and its implementation for the neutral beam profile measurement. Korea, Republic of: N. p., 1997. Web.
Lee, Seung Wook, Cho, Gyu Seong, & Cho, Yong Sub. Maximum entropy algorithm and its implementation for the neutral beam profile measurement. Korea, Republic of.
Lee, Seung Wook, Cho, Gyu Seong, and Cho, Yong Sub. 1997. "Maximum entropy algorithm and its implementation for the neutral beam profile measurement." Korea, Republic of.
@misc{etde_324124,
title = {Maximum entropy algorithm and its implementation for the neutral beam profile measurement}
author = {Lee, Seung Wook, Cho, Gyu Seong, and Cho, Yong Sub}
abstractNote = {A tomography algorithm to maximize the entropy of image using Lagrangian multiplier technique and conjugate gradient method has been designed for the measurement of 2D spatial distribution of intense neutral beams of KSTAR NBI (Korea Superconducting Tokamak Advanced Research Neutral Beam Injector), which is now being designed. A possible detection system was assumed and a numerical simulation has been implemented to test the reconstruction quality of given beam profiles. This algorithm has the good applicability for sparse projection data and thus, can be used for the neutral beam tomography. 8 refs., 3 figs. (Author)}
place = {Korea, Republic of}
year = {1997}
month = {Dec}
}