You need JavaScript to view this

Fuel management simulation for CANFLEX-RU in CANDU 6

Abstract

Fuel management simulations have been performed for CANFLEX-09% RU fuel in the CANDU 6 reactor. In this study, the bi-directional 4-bundle shift fuelling scheme was assumed. The lattice cell and time-average calculation were carried out. The refuelling simulation calculations were performed for 600 full power days. Time-averaged results show good axial power profile with the CANFLEX-RU fuel. During the simulation period, the maximum channel and bundle power were maintained below the licensing limit of CANDU 6 reactor. 7 refs., 4 figs. (Author)
Authors:
Jeong, Chang Joon; Suk, Ho Chun [1] 
  1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
Publication Date:
Dec 31, 1997
Product Type:
Conference
Report Number:
ETDE/KR-99732628; CONF-9710296-
Reference Number:
SCA: 210400; PA: KR-99:000288; EDB-99:035069; SN: 99002059915
Resource Relation:
Conference: Korean Nuclear Society autumn meeting, Taegu (Korea, Republic of), 24-25 Oct 1997; Other Information: PBD: 1997; Related Information: Is Part Of Proceedings of the korean nuclear society autumn meeting vol I, October 24-25, 1997 Taegu, Korea; PB: 797 p.
Subject:
21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS; FUEL MANAGEMENT; SIMULATION; CANDU TYPE REACTORS; FUEL ELEMENT CLUSTERS; NUCLEAR FUELS; FUEL CHANNELS; HOT CHANNEL
OSTI ID:
324089
Research Organizations:
Korean Nuclear Society, Taejon (Korea, Republic of)
Country of Origin:
Korea, Republic of
Language:
English
Other Identifying Numbers:
Other: ON: DE99732628; TRN: KR9900288
Availability:
OSTI as DE99732628
Submitting Site:
KR
Size:
pp. 147-151
Announcement Date:
Apr 01, 1999

Citation Formats

Jeong, Chang Joon, and Suk, Ho Chun. Fuel management simulation for CANFLEX-RU in CANDU 6. Korea, Republic of: N. p., 1997. Web.
Jeong, Chang Joon, & Suk, Ho Chun. Fuel management simulation for CANFLEX-RU in CANDU 6. Korea, Republic of.
Jeong, Chang Joon, and Suk, Ho Chun. 1997. "Fuel management simulation for CANFLEX-RU in CANDU 6." Korea, Republic of.
@misc{etde_324089,
title = {Fuel management simulation for CANFLEX-RU in CANDU 6}
author = {Jeong, Chang Joon, and Suk, Ho Chun}
abstractNote = {Fuel management simulations have been performed for CANFLEX-09% RU fuel in the CANDU 6 reactor. In this study, the bi-directional 4-bundle shift fuelling scheme was assumed. The lattice cell and time-average calculation were carried out. The refuelling simulation calculations were performed for 600 full power days. Time-averaged results show good axial power profile with the CANFLEX-RU fuel. During the simulation period, the maximum channel and bundle power were maintained below the licensing limit of CANDU 6 reactor. 7 refs., 4 figs. (Author)}
place = {Korea, Republic of}
year = {1997}
month = {Dec}
}