You need JavaScript to view this

Damage distribution and remnant life assessment of a super-heater outlet header used for long time

Abstract

This paper presents the results of investigation on evaluating damage distribution to base metals and welded joints in the thickness direction and evaluate damage on ligaments. Thick wall tested sample was the superheater outlet header component long term serviced in high pressure and temperature condition in thermal power plant. The simulate unused steel of component material was made from sample by suitable heat treatment, and the extent of damage was assessed based on a comparison of nondestructive and destructive test results between simulate unused and aged samples. Damage evaluation was also made by FEM structural stress analysis. (orig./MM)
Authors:
Hiroyuki, Okamura; [1]  Ryuichi, Ohotani; [2]  Kazuya, Fujii; [3]  Masashi, Nakashiro; Fumio, Takemasa; Hideo, Umaki; Tomiyasu, Masumura [4] 
  1. Science Univ. of Tokyo (Japan)
  2. Kyoto Univ. (Japan)
  3. Japan Power Engineering and Inspection Corp., Tokyo (Japan)
  4. Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)
Publication Date:
Nov 01, 1998
Product Type:
Conference
Report Number:
INIS-DE-0022; CONF-9710266-
Reference Number:
SCA: 200104; 360103; PA: DE-98:0GG178; EDB-99:018948; SN: 98002017872
Resource Relation:
Conference: 23. MPA seminar: safety and reliability of plant technology with special emphasis on nuclear technology - behaviour of pressurized components and systems at increased loading, 23. MPA-Seminar: Sicherheit und Verfuegbarkeit in der Anlagentechnik mit dem Schwerpunkt Kerntechnik - Verhalten von druckfuehrenden Komponenten und Systemen bei erhoehten Belastungen, Stuttgart (Germany), 1-2 Oct 1997; Other Information: PBD: [1998]; Related Information: Is Part Of 23. MPA-Seminar: Safety and reliability of plant technology with special emphasis on behaviour of pressurized components and systems at increased loading. Vol. 2. Papers 27-50; PB: 431 p.; 23. MPA-Seminar: Sicherheit und Verfuegbarkeit in der Anlagentechnik mit dem Schwerpunkt Verhalten von druckfuehrenden Komponenten und Systemen bei erhoehten Belastungen. Bd. 2. Vortraege 27-50
Subject:
20 FOSSIL-FUELED POWER PLANTS; 36 MATERIALS SCIENCE; DAMAGE; SERVICE LIFE; SUPERHEATERS; WELDED JOINTS; FOSSIL-FUEL POWER PLANTS; FINITE ELEMENT METHOD; STRESS ANALYSIS; STEEL-CRMO; CREEP; SIMULATION; STRESSES
OSTI ID:
307366
Research Organizations:
Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt
Country of Origin:
Germany
Language:
English
Other Identifying Numbers:
Other: ON: DE99704622; TRN: DE98GG178
Availability:
INIS; OSTI as DE99704622
Submitting Site:
DE
Size:
pp. 32.1-32.18
Announcement Date:
Feb 24, 1999

Citation Formats

Hiroyuki, Okamura, Ryuichi, Ohotani, Kazuya, Fujii, Masashi, Nakashiro, Fumio, Takemasa, Hideo, Umaki, and Tomiyasu, Masumura. Damage distribution and remnant life assessment of a super-heater outlet header used for long time. Germany: N. p., 1998. Web.
Hiroyuki, Okamura, Ryuichi, Ohotani, Kazuya, Fujii, Masashi, Nakashiro, Fumio, Takemasa, Hideo, Umaki, & Tomiyasu, Masumura. Damage distribution and remnant life assessment of a super-heater outlet header used for long time. Germany.
Hiroyuki, Okamura, Ryuichi, Ohotani, Kazuya, Fujii, Masashi, Nakashiro, Fumio, Takemasa, Hideo, Umaki, and Tomiyasu, Masumura. 1998. "Damage distribution and remnant life assessment of a super-heater outlet header used for long time." Germany.
@misc{etde_307366,
title = {Damage distribution and remnant life assessment of a super-heater outlet header used for long time}
author = {Hiroyuki, Okamura, Ryuichi, Ohotani, Kazuya, Fujii, Masashi, Nakashiro, Fumio, Takemasa, Hideo, Umaki, and Tomiyasu, Masumura}
abstractNote = {This paper presents the results of investigation on evaluating damage distribution to base metals and welded joints in the thickness direction and evaluate damage on ligaments. Thick wall tested sample was the superheater outlet header component long term serviced in high pressure and temperature condition in thermal power plant. The simulate unused steel of component material was made from sample by suitable heat treatment, and the extent of damage was assessed based on a comparison of nondestructive and destructive test results between simulate unused and aged samples. Damage evaluation was also made by FEM structural stress analysis. (orig./MM)}
place = {Germany}
year = {1998}
month = {Nov}
}