You need JavaScript to view this

ECR ion source for variable energy cyclotron

Abstract

Some performance characteristics of 6.4 GHz two stage ECR ion source which was under development at this centre is presented. The present ion source will facilitate acceleration of light heavy ions with the existing k=130 variable energy cyclotron. Multiply charged heavy ion (MCHI) beam from the source will also be utilized for atomic physics studies. Oxygen beam has already been used for ion implantation studies. The external injection system under development is nearing completion. Heavy ion beam from cyclotron is expected by end of 1995. (author).
Authors:
Bose, D K; Taki, G S; Nabhiraj, P Y; Pal, G; Dasgupta, B; Mallik, C; Das, S K; Bandopadhaya, D K; Bhandari, R K [1] 
  1. Variable Energy Cyclotron Centre, Calcutta (India)
Publication Date:
Sep 01, 1995
Product Type:
Conference
Report Number:
INS-J-182; CONF-9504228-
Reference Number:
SCA: 430301; PA: JPN-96:003180; EDB-96:081153; SN: 96001588585
Resource Relation:
Conference: 12. international workshop on ECR ion sources, Wako (Japan), 25-27 Apr 1995; Other Information: PBD: Sep 1995; Related Information: Is Part Of Proceedings of the 12th international workshop on ECR ion sources; Sekiguchi, Masayuki; Nakagawa, Takahide [eds.]; PB: 363 p.
Subject:
43 PARTICLE ACCELERATORS; ION SOURCES; ELECTRON CYCLOTRON-RESONANCE; ION BEAM INJECTION; CYCLOTRONS; LIGHT IONS; MULTICHARGED IONS; HEAVY IONS; INDIAN ORGANIZATIONS; ION IMPLANTATION; PERFORMANCE
OSTI ID:
226269
Research Organizations:
Tokyo Univ., Tanashi (Japan). Inst. for Nuclear Study
Country of Origin:
Japan
Language:
English
Other Identifying Numbers:
Other: ON: DE96725253; TRN: JP9603180
Availability:
INIS; OSTI as DE96725253
Submitting Site:
JPN
Size:
pp. 237-239
Announcement Date:

Citation Formats

Bose, D K, Taki, G S, Nabhiraj, P Y, Pal, G, Dasgupta, B, Mallik, C, Das, S K, Bandopadhaya, D K, and Bhandari, R K. ECR ion source for variable energy cyclotron. Japan: N. p., 1995. Web.
Bose, D K, Taki, G S, Nabhiraj, P Y, Pal, G, Dasgupta, B, Mallik, C, Das, S K, Bandopadhaya, D K, & Bhandari, R K. ECR ion source for variable energy cyclotron. Japan.
Bose, D K, Taki, G S, Nabhiraj, P Y, Pal, G, Dasgupta, B, Mallik, C, Das, S K, Bandopadhaya, D K, and Bhandari, R K. 1995. "ECR ion source for variable energy cyclotron." Japan.
@misc{etde_226269,
title = {ECR ion source for variable energy cyclotron}
author = {Bose, D K, Taki, G S, Nabhiraj, P Y, Pal, G, Dasgupta, B, Mallik, C, Das, S K, Bandopadhaya, D K, and Bhandari, R K}
abstractNote = {Some performance characteristics of 6.4 GHz two stage ECR ion source which was under development at this centre is presented. The present ion source will facilitate acceleration of light heavy ions with the existing k=130 variable energy cyclotron. Multiply charged heavy ion (MCHI) beam from the source will also be utilized for atomic physics studies. Oxygen beam has already been used for ion implantation studies. The external injection system under development is nearing completion. Heavy ion beam from cyclotron is expected by end of 1995. (author).}
place = {Japan}
year = {1995}
month = {Sep}
}