You need JavaScript to view this

Adaptation to the electronics of fast and highly efficient fission chambers; Adaptation a l'electronique de chambres a fission rapides et de grande efficacite

Abstract

When designing a fast and highly efficient sensor, not only optimal values of the sensor per se (nature of the filling gas, pressure, electric field, etc.), but also its adaptation to the cable of connection to the electronics must be taken into account. The author reports the development of the expression of the characteristic impedance of fission chambers and the determination of elementary tubes. He reports the theoretical study of the amplitude of pulses produced by a sensor in the case of a non-adapted sensor and in the case of an adapted sensor. It appears that an adapted chamber does not possess only benefits, but is an interesting solution only when the sensor collection time is very short and when the compliance with its speed is the essential objective. Some recommendations are made for the electronics characteristics, and for the connection cable (very low losses, which means a greater diameter than the current one)
Authors:
Publication Date:
Sep 04, 1968
Product Type:
Technical Report
Report Number:
CEA-N-1175; Report-2156/SER/1400
Resource Relation:
Other Information: Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS website for current contact and E-mail addresses: http://www.iaea.org/inis/Contacts/
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CEA SACLAY; CONNECTORS; COUNTING CIRCUITS; COUNTING TECHNIQUES; ELECTRIC CABLES; ELECTRIC IMPEDANCE; ELECTRICAL PROPERTIES; ELECTRONIC CIRCUITS; FISSION CHAMBERS; RADIATION DETECTION; RECOMMENDATIONS; SENSORS
OSTI ID:
22357410
Research Organizations:
Commissariat a l'Energie Atomique - CEA, Centre d'etudes Nucleaires de Saclay, Departement d'Electronique Generale, Service d'Electronique des Reacteurs (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR1501179062584
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
18 page(s)
Announcement Date:
Jul 17, 2015

Citation Formats

Buisson, Jacques. Adaptation to the electronics of fast and highly efficient fission chambers; Adaptation a l'electronique de chambres a fission rapides et de grande efficacite. France: N. p., 1968. Web.
Buisson, Jacques. Adaptation to the electronics of fast and highly efficient fission chambers; Adaptation a l'electronique de chambres a fission rapides et de grande efficacite. France.
Buisson, Jacques. 1968. "Adaptation to the electronics of fast and highly efficient fission chambers; Adaptation a l'electronique de chambres a fission rapides et de grande efficacite." France.
@misc{etde_22357410,
title = {Adaptation to the electronics of fast and highly efficient fission chambers; Adaptation a l'electronique de chambres a fission rapides et de grande efficacite}
author = {Buisson, Jacques}
abstractNote = {When designing a fast and highly efficient sensor, not only optimal values of the sensor per se (nature of the filling gas, pressure, electric field, etc.), but also its adaptation to the cable of connection to the electronics must be taken into account. The author reports the development of the expression of the characteristic impedance of fission chambers and the determination of elementary tubes. He reports the theoretical study of the amplitude of pulses produced by a sensor in the case of a non-adapted sensor and in the case of an adapted sensor. It appears that an adapted chamber does not possess only benefits, but is an interesting solution only when the sensor collection time is very short and when the compliance with its speed is the essential objective. Some recommendations are made for the electronics characteristics, and for the connection cable (very low losses, which means a greater diameter than the current one)}
place = {France}
year = {1968}
month = {Sep}
}