Abstract
The {sup 10}B based Jalousie detector is a replacement for {sup 3}He counter tubes, which are nowadays less affordable for large area detectors due to the {sup 3}He crisis. In this paper we investigate and verify the performance of the new {sup 10}B based detector concept and its adoption for the POWTEX diffractometer, which is designed for the detection of thermal neutrons with predicted detection efficiencies of 75–50% for neutron energies of 10–100 meV, respectively. The predicted detection efficiency has been verified by absolute measurements using neutrons with a wavelength of 1.17 Å (59 meV)
Modzel, G., E-mail: modzel@physi.uni-heidelberg;
[1]
Henske, M.;
[2]
Houben, A.;
[3]
Klein, M.;
[1]
CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)];
Köhli, M.;
Lennert, P.;
[1]
Meven, M.;
[4]
Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), Outstation at MLZ, 85747 Garching (Germany)];
Schmidt, C. J.;
[2]
GSI Detector Laboratory, Planckstr. 1, 64291 Darmstadt (Germany)];
Schmidt, U.;
[1]
Schweika, W.;
[5]
European Spallation Source ESS AB, SE-22100 Lund (Sweden)]
- Physikalisches Institut, Universität Heidelberg, Neuenheimer Feld 226, 69120 Heidelberg (Germany)
- CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)
- Institute of Inorganic Chemistry, RWTH Aachen University, Landoltweg 1, 52074 Aachen (Germany)
- Heinz Maier-Leibnitz Zentrum (MLZ), 85747 Garching (Germany)
- Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), 52425 Jülich (Germany)
Citation Formats
Modzel, G., E-mail: modzel@physi.uni-heidelberg, Henske, M., Houben, A., Klein, M., CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)], Köhli, M., Lennert, P., Meven, M., Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), Outstation at MLZ, 85747 Garching (Germany)], Schmidt, C. J., GSI Detector Laboratory, Planckstr. 1, 64291 Darmstadt (Germany)], Schmidt, U., Schweika, W., and European Spallation Source ESS AB, SE-22100 Lund (Sweden)].
Absolute efficiency measurements with the {sup 10}B based Jalousie detector.
Netherlands: N. p.,
2014.
Web.
doi:10.1016/J.NIMA.2014.01.007.
Modzel, G., E-mail: modzel@physi.uni-heidelberg, Henske, M., Houben, A., Klein, M., CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)], Köhli, M., Lennert, P., Meven, M., Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), Outstation at MLZ, 85747 Garching (Germany)], Schmidt, C. J., GSI Detector Laboratory, Planckstr. 1, 64291 Darmstadt (Germany)], Schmidt, U., Schweika, W., & European Spallation Source ESS AB, SE-22100 Lund (Sweden)].
Absolute efficiency measurements with the {sup 10}B based Jalousie detector.
Netherlands.
https://doi.org/10.1016/J.NIMA.2014.01.007
Modzel, G., E-mail: modzel@physi.uni-heidelberg, Henske, M., Houben, A., Klein, M., CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)], Köhli, M., Lennert, P., Meven, M., Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), Outstation at MLZ, 85747 Garching (Germany)], Schmidt, C. J., GSI Detector Laboratory, Planckstr. 1, 64291 Darmstadt (Germany)], Schmidt, U., Schweika, W., and European Spallation Source ESS AB, SE-22100 Lund (Sweden)].
2014.
"Absolute efficiency measurements with the {sup 10}B based Jalousie detector."
Netherlands.
https://doi.org/10.1016/J.NIMA.2014.01.007.
@misc{etde_22313526,
title = {Absolute efficiency measurements with the {sup 10}B based Jalousie detector}
author = {Modzel, G., E-mail: modzel@physi.uni-heidelberg, Henske, M., Houben, A., Klein, M., CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)], Köhli, M., Lennert, P., Meven, M., Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), Outstation at MLZ, 85747 Garching (Germany)], Schmidt, C. J., GSI Detector Laboratory, Planckstr. 1, 64291 Darmstadt (Germany)], Schmidt, U., Schweika, W., and European Spallation Source ESS AB, SE-22100 Lund (Sweden)]}
abstractNote = {The {sup 10}B based Jalousie detector is a replacement for {sup 3}He counter tubes, which are nowadays less affordable for large area detectors due to the {sup 3}He crisis. In this paper we investigate and verify the performance of the new {sup 10}B based detector concept and its adoption for the POWTEX diffractometer, which is designed for the detection of thermal neutrons with predicted detection efficiencies of 75–50% for neutron energies of 10–100 meV, respectively. The predicted detection efficiency has been verified by absolute measurements using neutrons with a wavelength of 1.17 Å (59 meV)}
doi = {10.1016/J.NIMA.2014.01.007}
journal = []
volume = {743}
journal type = {AC}
place = {Netherlands}
year = {2014}
month = {Apr}
}
title = {Absolute efficiency measurements with the {sup 10}B based Jalousie detector}
author = {Modzel, G., E-mail: modzel@physi.uni-heidelberg, Henske, M., Houben, A., Klein, M., CDT CASCADE Detector Technologies GmbH, Hans-Bunte-Str. 8–10, 69123 Heidelberg (Germany)], Köhli, M., Lennert, P., Meven, M., Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science (JCNS), Outstation at MLZ, 85747 Garching (Germany)], Schmidt, C. J., GSI Detector Laboratory, Planckstr. 1, 64291 Darmstadt (Germany)], Schmidt, U., Schweika, W., and European Spallation Source ESS AB, SE-22100 Lund (Sweden)]}
abstractNote = {The {sup 10}B based Jalousie detector is a replacement for {sup 3}He counter tubes, which are nowadays less affordable for large area detectors due to the {sup 3}He crisis. In this paper we investigate and verify the performance of the new {sup 10}B based detector concept and its adoption for the POWTEX diffractometer, which is designed for the detection of thermal neutrons with predicted detection efficiencies of 75–50% for neutron energies of 10–100 meV, respectively. The predicted detection efficiency has been verified by absolute measurements using neutrons with a wavelength of 1.17 Å (59 meV)}
doi = {10.1016/J.NIMA.2014.01.007}
journal = []
volume = {743}
journal type = {AC}
place = {Netherlands}
year = {2014}
month = {Apr}
}