You need JavaScript to view this

Possibilities of long duration generation of vapour of iodine 131 in the air for its trapping in French activated carbons; Possibilites de generation de longue duree dans l'air de vapeur d'iode 131 en vue de son piegeage par les charbons actifs francais

Miscellaneous:

Abstract

As previous studies performed on activated carbon showed that it was necessary to possess a long duration iodine generator to determine the scope of application of some advanced theories concerning the trap mechanism of different forms of radio-iodines, the authors present a generator which uses the high temperature oxidation of sodium iodide by an air stream or an oxygen stream. A version of this apparatus using a 5 Curie source is planned to check the operation of a trap of 100.000 m{sup 3}/h with a purification coefficient of 10{sup 4}, and aimed at being mounted on the venting circuit of a nuclear reactor enclosure [French] Les etudes que nous avons effectuees sur les charbons actifs nous ont montre qu'il etait necessaire de posseder un generateur d'iode de longue duree pour preciser le domaine d'application de certaines theories avancees concernant le mecanisme de piegeage des differentes formes de radioiodes. Un generateur utilisant l'oxydation de l'iodure de sodium a chaud par un courant d'air ou d'oxygene est decrit. Une version de cet appareil utilisant une source de 5 curies est prevue pour verifier le bon fonctionnement d'un piege de 100.000 m{sup 3}/h ayant un coefficient d'epuration de 10{sup 4} est destine a  More>>
Publication Date:
Dec 17, 1962
Product Type:
Miscellaneous
Report Number:
CEA-N-0413
Resource Relation:
Other Information: 11 refs.; Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS website for current contact and E-mail addresses: http://www.iaea.org/inis/Contacts/
Subject:
07 ISOTOPES AND RADIATION SOURCES; 12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; ACTIVATED CARBON; ADSORPTION; IODINE; IODINE 131; POLLUTION CONTROL EQUIPMENT; PURIFICATION; RADIATION PROTECTION; REACTOR PROTECTION SYSTEMS; SHIELDING; SODIUM IODIDES; TRAPPING; VENTILATION SYSTEMS
OSTI ID:
22306469
Research Organizations:
Commissariat a l'Energie Atomique - CEA, Service de Controle des Radiations et de Genie Radioactif (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR1403164012642
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
28 page(s)
Announcement Date:
Feb 14, 2015

Miscellaneous:

Citation Formats

Billard, F., Chevalier, G., and Pradel, J. Possibilities of long duration generation of vapour of iodine 131 in the air for its trapping in French activated carbons; Possibilites de generation de longue duree dans l'air de vapeur d'iode 131 en vue de son piegeage par les charbons actifs francais. France: N. p., 1962. Web.
Billard, F., Chevalier, G., & Pradel, J. Possibilities of long duration generation of vapour of iodine 131 in the air for its trapping in French activated carbons; Possibilites de generation de longue duree dans l'air de vapeur d'iode 131 en vue de son piegeage par les charbons actifs francais. France.
Billard, F., Chevalier, G., and Pradel, J. 1962. "Possibilities of long duration generation of vapour of iodine 131 in the air for its trapping in French activated carbons; Possibilites de generation de longue duree dans l'air de vapeur d'iode 131 en vue de son piegeage par les charbons actifs francais." France.
@misc{etde_22306469,
title = {Possibilities of long duration generation of vapour of iodine 131 in the air for its trapping in French activated carbons; Possibilites de generation de longue duree dans l'air de vapeur d'iode 131 en vue de son piegeage par les charbons actifs francais}
author = {Billard, F., Chevalier, G., and Pradel, J.}
abstractNote = {As previous studies performed on activated carbon showed that it was necessary to possess a long duration iodine generator to determine the scope of application of some advanced theories concerning the trap mechanism of different forms of radio-iodines, the authors present a generator which uses the high temperature oxidation of sodium iodide by an air stream or an oxygen stream. A version of this apparatus using a 5 Curie source is planned to check the operation of a trap of 100.000 m{sup 3}/h with a purification coefficient of 10{sup 4}, and aimed at being mounted on the venting circuit of a nuclear reactor enclosure [French] Les etudes que nous avons effectuees sur les charbons actifs nous ont montre qu'il etait necessaire de posseder un generateur d'iode de longue duree pour preciser le domaine d'application de certaines theories avancees concernant le mecanisme de piegeage des differentes formes de radioiodes. Un generateur utilisant l'oxydation de l'iodure de sodium a chaud par un courant d'air ou d'oxygene est decrit. Une version de cet appareil utilisant une source de 5 curies est prevue pour verifier le bon fonctionnement d'un piege de 100.000 m{sup 3}/h ayant un coefficient d'epuration de 10{sup 4} est destine a etre place sur le circuit de ventilation de l'enceinte d'un reacteur nucleaire. (auteurs)}
place = {France}
year = {1962}
month = {Dec}
}