Notes on the Start-Up of the Latina Power Station; Notes concernant le demarrage de la centrale nucleaire de Latina; Zapusk ehlektrostantsii Latina; Notas sobre la puesta en marcha de la central electrica de Latina

Abstract

Information is given on the start-up of the first Italian nuclear power plant, the Latin Power Station, designed for an electrical output of 200 MW, incorporating a natural uranium-gas-graphite reactor. After a brief description of the main characteristics of the station, details are given on die performance of the final tests of the plant, on the fuel loading and on the sequence of commissioning operations, measurements and controls subsequent to the criticality attained. The operations for the start-up and connection of the station to the electrical network are treated. The organization problems relevant to the station operation including personnel preparation and qualification, safety measures, are also illustrated. (author) [French] Le memoire donne des renseignements sur le demarrage de la premiere centrale nucleaire italienne, la centrale de Latina, dont la puissance electrique est de 200 MW et qui fonctionne avec un reacteur du type uranium naturel-gaz-graphite. Apres une breve description des caracteristiques essentielles de la centrale, des explications detaillees sont donnees sur les resultats des derniers essais auxquels elle a ete soumise, sur le chargement du combustible et sur la serie des operations de mise en service, des mesures et des verifications auxquelles il a ete procede lorsque l'etat critique a  More>>
Authors:
Calabria, G.; Gualtieri, G. [1] 
  1. AGIP Nucleare, Milano (Italy)
Publication Date:
Oct 15, 1963
Product Type:
Conference
Resource Relation:
Conference: Conference on Operating Experience with Power Reactors, Vienna (Austria), 4-8 Jun 1963; Other Information: 5 refs.; Related Information: In: Operating Experience with Power Reactors. Proceedings of the Conference on Operating Experience with Power Reactors. Vol. II| 428 p.
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; CRITICALITY; LATINA REACTOR; NATURAL URANIUM; PERFORMANCE; PERSONNEL; REACTOR COMMISSIONING; REACTOR CONTROL SYSTEMS; REACTOR FUELING; REACTOR OPERATION; REACTOR SAFETY; REACTOR START-UP
OSTI ID:
22108185
Research Organizations:
International Atomic Energy Agency, Vienna (Austria)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
Other: ISSN 0074-1884; TRN: XA13R0407065996
Submitting Site:
INIS
Size:
page(s) 63-81
Announcement Date:
Jun 27, 2013

Citation Formats

Calabria, G., and Gualtieri, G. Notes on the Start-Up of the Latina Power Station; Notes concernant le demarrage de la centrale nucleaire de Latina; Zapusk ehlektrostantsii Latina; Notas sobre la puesta en marcha de la central electrica de Latina. IAEA: N. p., 1963. Web.
Calabria, G., & Gualtieri, G. Notes on the Start-Up of the Latina Power Station; Notes concernant le demarrage de la centrale nucleaire de Latina; Zapusk ehlektrostantsii Latina; Notas sobre la puesta en marcha de la central electrica de Latina. IAEA.
Calabria, G., and Gualtieri, G. 1963. "Notes on the Start-Up of the Latina Power Station; Notes concernant le demarrage de la centrale nucleaire de Latina; Zapusk ehlektrostantsii Latina; Notas sobre la puesta en marcha de la central electrica de Latina." IAEA.
@misc{etde_22108185,
title = {Notes on the Start-Up of the Latina Power Station; Notes concernant le demarrage de la centrale nucleaire de Latina; Zapusk ehlektrostantsii Latina; Notas sobre la puesta en marcha de la central electrica de Latina}
author = {Calabria, G., and Gualtieri, G.}
abstractNote = {Information is given on the start-up of the first Italian nuclear power plant, the Latin Power Station, designed for an electrical output of 200 MW, incorporating a natural uranium-gas-graphite reactor. After a brief description of the main characteristics of the station, details are given on die performance of the final tests of the plant, on the fuel loading and on the sequence of commissioning operations, measurements and controls subsequent to the criticality attained. The operations for the start-up and connection of the station to the electrical network are treated. The organization problems relevant to the station operation including personnel preparation and qualification, safety measures, are also illustrated. (author) [French] Le memoire donne des renseignements sur le demarrage de la premiere centrale nucleaire italienne, la centrale de Latina, dont la puissance electrique est de 200 MW et qui fonctionne avec un reacteur du type uranium naturel-gaz-graphite. Apres une breve description des caracteristiques essentielles de la centrale, des explications detaillees sont donnees sur les resultats des derniers essais auxquels elle a ete soumise, sur le chargement du combustible et sur la serie des operations de mise en service, des mesures et des verifications auxquelles il a ete procede lorsque l'etat critique a ete atteint. Les operations de demarrage et de raccordement de la centrale au reseau electrique sont etudiees dans le memoire, ainsi que les problemes d'organisation que pose l 'exploitation de la centrale, notamment en ce qui concerne la formation du personnel et les mesures de securite. (author) [Spanish] Se comunican datos sobre la puesta en marcha de la primera central nucleoelectrica italiana, en Latina, proyectada para desarrollar una potencia de 200 MW (e), que se basa en un reactor de uranio natural moderado por grafito u refrigerado por gas. Despues de describir brevemente las caracteristicas de la central, se dan detalles sobre el desarrollo de los ensayos finales, sobre la carga del combustible y el orden en que se ejecutaron las operaciones de puesta en marcha y sobre las determinaciones y maniobras de regulacion posteriores al estado critico. Se resenan asimismo las operaciones iniciales de generacion y conexion de la central con la red electrica. Por ultimo, se mencionan los problemas de organizacion derivados de la explotacion de la central, incluyendo la preparacion y formacion profesional del personal y las medidas de seguridad adoptadas. (author) [Russian] Privoditsya informatsiya o zapuske pervoj ital'yanskoj atomnoj ehlektrostantsii Latina moshchnost'yu 200 mgvt. Reaktor rabotaet na prirodnom urane s grafitovym zamedlitelem i gazovym okhlazhdeniem. Posle kratkogo opisaniya osnovnykh kharakteristik ehlektrostantsii privodyatsya podrobnye dannye otnositel'no provedeniya zaklyuchitel'nykh ispytanij stantsii'', toplivnoj zagruzki i poryadka ehkspluatatsii, izmerenij i upravleniya s dovedeniem do kriticheskogo sostoyaniya. Daetsya ob''yasnenie raboty po zapusku i vklyucheniyu stantsii v ehlektroset'. Izlagayutsya takzhe problemy, svyazannye s ehkspluatatsiej stantsii, v tom chisle podgotovka personela i ego kvalifikatsiya, mery po bezopasnosti. (author)}
place = {IAEA}
year = {1963}
month = {Oct}
}