You need JavaScript to view this

A New Apparatus for Inelastic, Quasi-Elastic and Elastic Cold Neutron Measurements; Un nouveau appareil pour les mesures de diffusion inelastique , quasi-elastique et elastique des neutrons lents; Novyj pribor dlya izmereniya neuprugogo, kvaziuprugogo i uprugogo rasseyaniya kholodnykh nejtrohov; Nuevo aparato para mediciones inelastic as, cuasi elasticas y elasticas de neutrones frios

Conference:

Abstract

A new chopper apparatus for use at the Brookhaven High Flux Beam Reactor is now under construction. It is a three-element phased rotof system. The rotors are 80 cm in diameter, run at a maximum speed of 15000 rev/min, and are designed to give three neutron bursts of monochromatic neutrons per revolution. Two rotors spin about a horizontal axis whereas the third operates vertically. The system can be operated with either one, two or three of the chopper elements, depending on the type of measurement that is completed. For inelastic measurements where the neutron gains energy, a double rotor system will be most useful. For this configuration the burst time and wave length spread (full widths at 1/2 maximum) will be 16 {mu}s and 0.16 A for 4 A incident neutrons, and the intensity at the sample (4 x 1.6 cm) will be 2 x 10{sup 6} n/s. For quasi-elastic and elastic neutron measurements the three-rotor configuration will be best suited. The corresponding burst time and wave length spread can be as small as 8 {mu}s and 0.04 A giving an intensity of 10{sup 4} n/s on a sample of (4 X 0.8 c m ), The wave length and  More>>
Authors:
Otnes, K; Palevsky, H [1] 
  1. Brookhaven National Laboratory, Upton, NY (United States)
Publication Date:
Jan 15, 1963
Product Type:
Conference
Resource Relation:
Conference: Symposium on Inelastic Scattering of Neutrons in Solids and Liquids, Chalk River (Canada), 10-14 Sep 1962; Other Information: Abstract also available in Russian; 4 figs., 2 tabs., 9 refs.; Related Information: In: Inelastic Scattering of Neutrons in Solids and Liquids. V. I. Proceedings of the Symposium on Inelastic Scattering of Neurons in Solids and Liquids| 486 p.
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY; COLD NEUTRONS; GAIN; HFBR REACTOR; MONOCHROMATIC RADIATION; ROTORS; SPIN; TIME RESOLUTION; WAVELENGTHS
OSTI ID:
22086590
Research Organizations:
International Atomic Energy Agency, Vienna (Austria); United Nations Educational, Scientific and Cultural Organization (France)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
Other: ISSN 0074-1884; TRN: XA13R0076045028
Submitting Site:
INIS
Size:
page(s) 95-106
Announcement Date:
Apr 18, 2013

Conference:

Citation Formats

Otnes, K, and Palevsky, H. A New Apparatus for Inelastic, Quasi-Elastic and Elastic Cold Neutron Measurements; Un nouveau appareil pour les mesures de diffusion inelastique , quasi-elastique et elastique des neutrons lents; Novyj pribor dlya izmereniya neuprugogo, kvaziuprugogo i uprugogo rasseyaniya kholodnykh nejtrohov; Nuevo aparato para mediciones inelastic as, cuasi elasticas y elasticas de neutrones frios. IAEA: N. p., 1963. Web.
Otnes, K, & Palevsky, H. A New Apparatus for Inelastic, Quasi-Elastic and Elastic Cold Neutron Measurements; Un nouveau appareil pour les mesures de diffusion inelastique , quasi-elastique et elastique des neutrons lents; Novyj pribor dlya izmereniya neuprugogo, kvaziuprugogo i uprugogo rasseyaniya kholodnykh nejtrohov; Nuevo aparato para mediciones inelastic as, cuasi elasticas y elasticas de neutrones frios. IAEA.
Otnes, K, and Palevsky, H. 1963. "A New Apparatus for Inelastic, Quasi-Elastic and Elastic Cold Neutron Measurements; Un nouveau appareil pour les mesures de diffusion inelastique , quasi-elastique et elastique des neutrons lents; Novyj pribor dlya izmereniya neuprugogo, kvaziuprugogo i uprugogo rasseyaniya kholodnykh nejtrohov; Nuevo aparato para mediciones inelastic as, cuasi elasticas y elasticas de neutrones frios." IAEA.
@misc{etde_22086590,
title = {A New Apparatus for Inelastic, Quasi-Elastic and Elastic Cold Neutron Measurements; Un nouveau appareil pour les mesures de diffusion inelastique , quasi-elastique et elastique des neutrons lents; Novyj pribor dlya izmereniya neuprugogo, kvaziuprugogo i uprugogo rasseyaniya kholodnykh nejtrohov; Nuevo aparato para mediciones inelastic as, cuasi elasticas y elasticas de neutrones frios}
author = {Otnes, K, and Palevsky, H}
abstractNote = {A new chopper apparatus for use at the Brookhaven High Flux Beam Reactor is now under construction. It is a three-element phased rotof system. The rotors are 80 cm in diameter, run at a maximum speed of 15000 rev/min, and are designed to give three neutron bursts of monochromatic neutrons per revolution. Two rotors spin about a horizontal axis whereas the third operates vertically. The system can be operated with either one, two or three of the chopper elements, depending on the type of measurement that is completed. For inelastic measurements where the neutron gains energy, a double rotor system will be most useful. For this configuration the burst time and wave length spread (full widths at 1/2 maximum) will be 16 {mu}s and 0.16 A for 4 A incident neutrons, and the intensity at the sample (4 x 1.6 cm) will be 2 x 10{sup 6} n/s. For quasi-elastic and elastic neutron measurements the three-rotor configuration will be best suited. The corresponding burst time and wave length spread can be as small as 8 {mu}s and 0.04 A giving an intensity of 10{sup 4} n/s on a sample of (4 X 0.8 c m ), The wave length and time resolution are adjustable between the above two limits in such a way as to obtain the maximum neutron intensity for a given experiment. (author) [French] Un nouveau selecteur destine au reacteur a haut flux de Brookhaven est actuellement en construction. Il s'agit d'un dispositif a trois rotors dephasables. Les rotors ont un diametre de 80 cm, tournent a une vitesse maximum de 15 000 tours pat minute et sont concus de maniere a fournir trois bouffees de neutrons monochromatiques a chaque tour. Deux rotors tournent autour d'un axe horizontal, le troisieme, autour d'un axe vertical. Le dispositif peut fonctionner avec un, deux ou trois elements, selon le type de mesure que l'on se propose de faire. Pour les mesures de diffusion inelastique ou les neutrons gagnent de l'energie, un dispositif a deux rotors sera tres utile. Pour cette configuation, la duree et la despersion de la longueur d'onde (largeur totale a mi-hauteur) seront respectivement de 16 {mu}s et 0,16 A pour des neutrons incidents ayant une longueur d'onde de 4 A; l'intensite de la bouffee sur l'echantillon (4 x 1,6 cm) sera de 2 x 10{sup 6} n/s pouf mesures de diffusion quasi-elastique et elastique, la configuration a trois rotors conviendra parfaitement. La duree de la bouffee et la dispersion de longueur d'onde correspondante peuvent atteindre des valeurs aussi faibles que 8 {mu}s et 0, 04 A, ce qui donne une intensite de 10{sup 4} n/s sur un echantillon de 4 x 0, 8 cm. La longueur d'onde et la resolution en temps peuvent etre ajustees entre les; deux limites susmentionnees, de maniere a obtenir l'intensite de flux maximum pour une experience determinee. (author) [Spanish] Se esta construyendo un nuevo selector mecanico destinado al reactor de flujo intenso de Brookhaven. El aparato es del tipo de tres elementos rotores en fase. Los rotores, de 80 cm de diametro, giran a una velo- cidad maxima de 15000 rev/min y se han disenado de modo que emitan tres rafagas de neutrones monocromaticos por revolucion. Dos de los rotores giran alrededor de un eje horizontal, mientras que el tercero lo hace verticalmente. El sistma puede funcionar con uno, dos or tres elementos selectores, segun el tipo de medicion que se quiera efectuar. Para las mediciones inelasticas en que los neutrones ganan energia, lo mas indicado es utilizar un sistema de dos rotores. En este sistema, la duracion de las rafagas sera de 16 {mu}s y el ensanchamiento de longitudes de onda (amplitud plena a la mitad del valor maximo) de 0,16 A para neutrones incidentes de 4 A; la intensidd en la muestra (4 x 1,6 cm) sera de 2 x 10{sup 6} n/s. para las mediciones cuasi elasticas y elasticas resultara mas apropiado el sistema de tres rotores. La duracion de las rafagas y el ensanchamiento de longitudes de onda pueden llegar a un minimo de 8 {mu}s y 0,04 A, respectivamente, lo que representa una intensidad de 10{sup 4} n/s en una muestra de 4 x 0,8 cm. La longitud de onda y la resolucion en tiempo pueden graduarse entre los dos limites citados, de modo que se obtenga la intensidad neutronica maxima para un experimento determinado. (author)}
place = {IAEA}
year = {1963}
month = {Jan}
}