A Low-Level Geiger-Counter for Tritium; Compteur Geiger a faible mouvement propre pour le tritium; Schetchik Gejgera s nizkim urovnem dlya tritiya; Contador Geiger de baja actividad de fondo para tritio

Abstract

A cylindrical counter tube of volume 11 l was constructed which contains a number of anticoincidence wires surrounding a 2.9 l effective-volume centre-counter. The centre counter is separated from the anticoincidence section by a thin aluminized Hostaphan foil. Details of the construction are given. The counter filling gas consists of 30 mm ethylene, 40 mm argon and up to 700 mm sample hydrogen. An external quenching circuit with a 7 msec dead time effectively eliminates after-pulses. In a 30 cm iron shield, the counting rates of the centre counter with dead hydrogen gas are 350 counts/min without and about 3 counts/min with the anticoincidence circuit in operation. If it is assumed that 1 count/min above background is significant, a T/H ratio of as low as 10{sup -16} can be measured without isotope enrichment. Experiments are in progress to check the longtime stability of the arrangement. (author) [French] Les auteurs ont monte un tube compteur cylindrique d'un volume de 11 litres qui contient un certain nombre de conducteurs d'anticoincidence entourant un compteur central d'un volume reel de 2,9 litres. Ce compteur central est separe de la zone d'anticoincidence par une feuille mince d' ''Hostaphan'' recouverte d'aluminium. Les auteurs donnent des details  More>>
Authors:
Von Buttlar, H; Stahl, W [1] 
  1. Technische Hochschule, Darmstadt (Germany)
Publication Date:
Jan 15, 1962
Product Type:
Conference
Resource Relation:
Conference: Symposium on Tritium in the Physical and Biological Sciences, Vienna (Austria), 3-10 May 1961; Other Information: 5 figs., 1 tab., 7 refs.; Related Information: In: Tritium in the Physical and Biological Sciences. V. 1. Proceedings of a Symposium| 380 p.
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ANTICOINCIDENCE; ARGON; CONSTRUCTION; COUNTING RATES; DEAD TIME; ETHYLENE; HYDROGEN; ISOTOPE SEPARATION; QUENCHING; STABILITY; TRITIUM
OSTI ID:
22028527
Research Organizations:
International Atomic Energy Agency, Vienna (Austria)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
Other: ISSN 0074-1884; TRN: XA12R0279116793
Submitting Site:
INIS
Size:
page(s) 325-331
Announcement Date:
Jan 24, 2013

Citation Formats

Von Buttlar, H, and Stahl, W. A Low-Level Geiger-Counter for Tritium; Compteur Geiger a faible mouvement propre pour le tritium; Schetchik Gejgera s nizkim urovnem dlya tritiya; Contador Geiger de baja actividad de fondo para tritio. IAEA: N. p., 1962. Web.
Von Buttlar, H, & Stahl, W. A Low-Level Geiger-Counter for Tritium; Compteur Geiger a faible mouvement propre pour le tritium; Schetchik Gejgera s nizkim urovnem dlya tritiya; Contador Geiger de baja actividad de fondo para tritio. IAEA.
Von Buttlar, H, and Stahl, W. 1962. "A Low-Level Geiger-Counter for Tritium; Compteur Geiger a faible mouvement propre pour le tritium; Schetchik Gejgera s nizkim urovnem dlya tritiya; Contador Geiger de baja actividad de fondo para tritio." IAEA.
@misc{etde_22028527,
title = {A Low-Level Geiger-Counter for Tritium; Compteur Geiger a faible mouvement propre pour le tritium; Schetchik Gejgera s nizkim urovnem dlya tritiya; Contador Geiger de baja actividad de fondo para tritio}
author = {Von Buttlar, H, and Stahl, W}
abstractNote = {A cylindrical counter tube of volume 11 l was constructed which contains a number of anticoincidence wires surrounding a 2.9 l effective-volume centre-counter. The centre counter is separated from the anticoincidence section by a thin aluminized Hostaphan foil. Details of the construction are given. The counter filling gas consists of 30 mm ethylene, 40 mm argon and up to 700 mm sample hydrogen. An external quenching circuit with a 7 msec dead time effectively eliminates after-pulses. In a 30 cm iron shield, the counting rates of the centre counter with dead hydrogen gas are 350 counts/min without and about 3 counts/min with the anticoincidence circuit in operation. If it is assumed that 1 count/min above background is significant, a T/H ratio of as low as 10{sup -16} can be measured without isotope enrichment. Experiments are in progress to check the longtime stability of the arrangement. (author) [French] Les auteurs ont monte un tube compteur cylindrique d'un volume de 11 litres qui contient un certain nombre de conducteurs d'anticoincidence entourant un compteur central d'un volume reel de 2,9 litres. Ce compteur central est separe de la zone d'anticoincidence par une feuille mince d' ''Hostaphan'' recouverte d'aluminium. Les auteurs donnent des details sur le montage de l'appareil. Le melange gazeux remplissant le compteur se compose d'ethylene (30 mm), d'argon (40 mm) et de l'echantillon d'hydrogene (jusqu' a 700 mm). Un circuit coupeur externe ayant un temps mort de 7 ms elimine efficacement les impulsions retardees. Avec une protection de fer de 30 cm, les taux de comptage du compteur central, rempli d'hydrogene inerte, sont de 350 coups par minute et d'environ 3 coups par minute, selon que le circuit d'anticoincidence fonctionne ou non. Si l'on suppose qu'un coup par minute au-dessus du bruit de fond est significatif, on peut mesurer des rapports T/H jusqu' a 10{sup -16} sans avoir a proceder a un enrichissement. On effectue actuellement des experiences pour controler la stabilite a long terme du systeme. (author) [Spanish] Contador Geiger de baja actividad de fondo para tritio. Los autores construyeron un tubo contador cilindrico de 11 l que contiene una serie de conductores de anticoincidencia en torno a un contador central de 2,9 l de volumen efectivo. La seccion de anticoincidencia esta separada del contador central por una delgada hoja de Hostaphan aluminizada. En el trabajo figura una serie de detalles constructivos. El gas que llena el contador consiste en una mezcla de etileno a 30 mm, de argon a 40 mm y la muestra de hidrogeno hasta 700 mm. Un circuito de extincion externo, cuyo tiempo muerto es de 7 ms, elimina eficazmente todos los impulsos demorados. Con un blindaje de hierro de 30 cm, el indice de recuento del contador central con hidrogeno gaseoso inerte es de 350 impulsos/min cuando el circuito de anticoincidencia no funciona y de unos 3 impulsos/min en el caso contrario. Suponiendo que un valor de 1 impulso/min por encima de la actividad de fondo sea significativo, resulta posible medir razones T/H muy pequenas, hasta 10{sup -16}, sin necesidad de proceder a un enriquecimiento isotopico. Se siguen realizando experimentos para verificar la estabilidad a largo plazo del dispositivo. (author) [Russian] Byla skonstruirovan a tsilindricheskaya trubka s ob{sup e}mom v 11 litrov, kotoraya soderzhit ryad provodov antisovpadeniya, okhvatyvayushchikh tsentral'nuyu chast' schetchika emkost'yu v 2,9 litra. TSentral'naya chast' schetchika otdelena ot sektsii antisovpadeniya tonkoj alyuminirovannoj Gostafanovoj fol'goj. Privodyatsya podrobnye dannye konstruktsii. Gaz dlya napolneniya schetchika sostoit iz 30 torr ehtilena, 40 torr argona i do 700 torr obraztsa vodoroda. Vneshnyaya tsep' gasheniya s mertvym vremenem v 7 msek. uspeshno ustranyaet posleduyushchie impul'sy. V 30 cm zheleznom ehkrane skorost' otcheta tsentral'noj chasti schetchika s ''mertvym'' vodorodnym gazom sostavlyaet 350 otschetov v minutu bez tsepi antisovpadeniya i okolo 3 otschetov v minutu s tsep'yu antisovpadeniya . Esli predpolozhit', chto 1 otschet v minutu vyshe fona yavlyaetsya znachitel'nym, to dazhe takoe nizkoe sootnoshenie T/H kak 10{sup -16} mozhno izmerit' bez obogashcheniya izotopov. Vedutsya ehksperimenty po proverke raboty ustrojstva na prodolzhitel'nost' vremeni. (author)}
place = {IAEA}
year = {1962}
month = {Jan}
}