Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria

Abstract

The Compton current produced by X-rays and {gamma}-rays in the 0.3 to 3 MeV range is proportional to the radiant energy flux. Therefore the intensity of the current can be used as a measure of radiation dose. The present paper describes a radiation receiver and electrical measuring system suitable for Compton current measurements and results obtained with this device under irradiation from a 2000 curie Co{sup 60} source. (author) [French] Le courant de Compton produit par des rayons X et {gamma} dans le domaine d'energies compris entre 0,3 et 3 MeV est proportionnel au flux d'energie rayonnante. C'est pourquoi l'intensite du courant peut servir de mesure de la dose de rayonnements. Le memoire decrit un ensemble, appareil recepteur de rayonnements et appareil de mesure electrique, permettant de mesurer le courant de Compton et il expose les resultats obtenus, au moyen de ce dispositif, sous irradiation par une source de Co{sup 60} de 2000 curies. (author) [Spanish] La corriente de Compton producida por rayos X y rayos {gamma} de energia comprendida entre 0,3 y 3 MeV es proporcional al flujo de energia radiante. Por consiguiente, la intensidad de la corriente puede servir para medir la dosis de radiacion. En este trabajo  More>>
Authors:
Gross, Bernhard [1] 
  1. National Institute of Technology, Rio de Janeiro (Brazil)
Publication Date:
Jun 15, 1960
Product Type:
Conference
Resource Relation:
Conference: Symposium on Metrology of Radionuclides, Vienna (Austria), 14-16 Oct 1959; Other Information: 3 figs., 1 ref.; Related Information: In: Metrology of Radionuclides. Proceedings of a Symposium| 488 p.
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; COBALT 60; CURRENTS; DOSEMETERS; EQUIPMENT; IRRADIATION; MEASURING METHODS; MEV RANGE; RADIATION DOSES; X RADIATION
OSTI ID:
22025789
Research Organizations:
International Atomic Energy Agency, Vienna (Austria)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
Other: ISSN 0074-1884; TRN: XA12R0175113082
Submitting Site:
INIS
Size:
page(s) 413-417
Announcement Date:
Jan 17, 2013

Citation Formats

Gross, Bernhard. Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria. IAEA: N. p., 1960. Web.
Gross, Bernhard. Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria. IAEA.
Gross, Bernhard. 1960. "Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria." IAEA.
@misc{etde_22025789,
title = {Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria}
author = {Gross, Bernhard}
abstractNote = {The Compton current produced by X-rays and {gamma}-rays in the 0.3 to 3 MeV range is proportional to the radiant energy flux. Therefore the intensity of the current can be used as a measure of radiation dose. The present paper describes a radiation receiver and electrical measuring system suitable for Compton current measurements and results obtained with this device under irradiation from a 2000 curie Co{sup 60} source. (author) [French] Le courant de Compton produit par des rayons X et {gamma} dans le domaine d'energies compris entre 0,3 et 3 MeV est proportionnel au flux d'energie rayonnante. C'est pourquoi l'intensite du courant peut servir de mesure de la dose de rayonnements. Le memoire decrit un ensemble, appareil recepteur de rayonnements et appareil de mesure electrique, permettant de mesurer le courant de Compton et il expose les resultats obtenus, au moyen de ce dispositif, sous irradiation par une source de Co{sup 60} de 2000 curies. (author) [Spanish] La corriente de Compton producida por rayos X y rayos {gamma} de energia comprendida entre 0,3 y 3 MeV es proporcional al flujo de energia radiante. Por consiguiente, la intensidad de la corriente puede servir para medir la dosis de radiacion. En este trabajo se describen un receptor de radiaciones y un sistema de medicion electrica apropiados para determinar la intensidad de la corriente de Compton, asi como los resultados obtenidos mediante este dis- positivo cuando se irradia con una fuente de Co{sup 60} de 2000 curies. (author) [Russian] Komptonovskij potok, obrazuemyj rentgenovskim i luchami i {gamma}-luchami v predelakh ot 0,3 do 3 mehv, proportsionale n potoku luchistoj ehnergii. Poehtomu intensivnost' potoka mozhet byt' ispol'zovana dlya izmereniya dozy radiatsii. V nastoyashchem dokumente opisyvayutsya radiatsionny j priemnik i ehlektricheskaya izmeritel'naya sistema, prigodnye dlya izmerenij s pomoshch'yu komptonovskog o potoka, i rezul'taty, poluchennye s pomoshch'yu ehtogo ustrojstva v khode oblucheniya istochnikom So{sup 60} moshchnost'yu ot 2000 kyuri. (author)}
place = {IAEA}
year = {1960}
month = {Jun}
}