Abstract
This paper is presenting results obtained with the DIADYN installation after replacing its vacuum electron source (VES{sub L}V) with a plasma electron source (PES{sub L}V). DIADYN is a low energy laboratory equipment operating with 10 to 50 keV electron beams and designed to help realize non-destructive diagnosis and dynamics for low energy electron beams but also to be used in future material irradiations. The results presented here regard the beam diagnosis and dynamics made with beams obtained from the newly replaced plasma source. We discuss both results obtained in experimental dynamics and dynamics calculation results for electron beams extracted from the SEP{sub L}V source.
Toader, D;
Craciun, G;
Manaila, E;
Oproiu, C;
[1]
Marghitu, S
[2]
- National Institute of Research for Laser, Plasma and Radiation Physics Bucuresti (Romania)
- ICPE Electrostatica S.A - Bucuresti (Romania)
Citation Formats
Toader, D, Craciun, G, Manaila, E, Oproiu, C, and Marghitu, S.
Electron Beam Diagnosis and Dynamics using DIADYN Plasma Source.
Egypt: N. p.,
2009.
Web.
Toader, D, Craciun, G, Manaila, E, Oproiu, C, & Marghitu, S.
Electron Beam Diagnosis and Dynamics using DIADYN Plasma Source.
Egypt.
Toader, D, Craciun, G, Manaila, E, Oproiu, C, and Marghitu, S.
2009.
"Electron Beam Diagnosis and Dynamics using DIADYN Plasma Source."
Egypt.
@misc{etde_21416250,
title = {Electron Beam Diagnosis and Dynamics using DIADYN Plasma Source}
author = {Toader, D, Craciun, G, Manaila, E, Oproiu, C, and Marghitu, S}
abstractNote = {This paper is presenting results obtained with the DIADYN installation after replacing its vacuum electron source (VES{sub L}V) with a plasma electron source (PES{sub L}V). DIADYN is a low energy laboratory equipment operating with 10 to 50 keV electron beams and designed to help realize non-destructive diagnosis and dynamics for low energy electron beams but also to be used in future material irradiations. The results presented here regard the beam diagnosis and dynamics made with beams obtained from the newly replaced plasma source. We discuss both results obtained in experimental dynamics and dynamics calculation results for electron beams extracted from the SEP{sub L}V source.}
place = {Egypt}
year = {2009}
month = {Nov}
}
title = {Electron Beam Diagnosis and Dynamics using DIADYN Plasma Source}
author = {Toader, D, Craciun, G, Manaila, E, Oproiu, C, and Marghitu, S}
abstractNote = {This paper is presenting results obtained with the DIADYN installation after replacing its vacuum electron source (VES{sub L}V) with a plasma electron source (PES{sub L}V). DIADYN is a low energy laboratory equipment operating with 10 to 50 keV electron beams and designed to help realize non-destructive diagnosis and dynamics for low energy electron beams but also to be used in future material irradiations. The results presented here regard the beam diagnosis and dynamics made with beams obtained from the newly replaced plasma source. We discuss both results obtained in experimental dynamics and dynamics calculation results for electron beams extracted from the SEP{sub L}V source.}
place = {Egypt}
year = {2009}
month = {Nov}
}