Abstract
On various occasions during pulse mode operation the shim and regulating control rods would drop when the pulse rod was withdrawn. Subsequent investigation traced the problem to the pulse rod shock absorber which was found to be low in hydraulic fluid. The results of the investigation, the corrective action taken, and a method for measuring the shock absorber fluid level are presented. (author)
Citation Formats
Aderhold, H. C.
Low fluid level in pulse rod shock absorber.
United States: N. p.,
1974.
Web.
Aderhold, H. C.
Low fluid level in pulse rod shock absorber.
United States.
Aderhold, H. C.
1974.
"Low fluid level in pulse rod shock absorber."
United States.
@misc{etde_21217727,
title = {Low fluid level in pulse rod shock absorber}
author = {Aderhold, H. C.}
abstractNote = {On various occasions during pulse mode operation the shim and regulating control rods would drop when the pulse rod was withdrawn. Subsequent investigation traced the problem to the pulse rod shock absorber which was found to be low in hydraulic fluid. The results of the investigation, the corrective action taken, and a method for measuring the shock absorber fluid level are presented. (author)}
place = {United States}
year = {1974}
month = {Jul}
}
title = {Low fluid level in pulse rod shock absorber}
author = {Aderhold, H. C.}
abstractNote = {On various occasions during pulse mode operation the shim and regulating control rods would drop when the pulse rod was withdrawn. Subsequent investigation traced the problem to the pulse rod shock absorber which was found to be low in hydraulic fluid. The results of the investigation, the corrective action taken, and a method for measuring the shock absorber fluid level are presented. (author)}
place = {United States}
year = {1974}
month = {Jul}
}