Foreign Material Exclusion Program at CNE Cernavoda Nuclear Generating Station

Abstract

In the face of a continuing attention to operations and maintenance costs at nuclear power plants, the future of the industry depends largely upon increasing plant availability and improving operating efficiency. The success in achieving these objectives is dependent upon the success of each plant's equipment maintenance program. Preventing the introduction of foreign materials into a nuclear power plant system or component requires a careful, thoughtful, and professional approach by all site personnel. This paper describes a proactive approach to prevent the introduction of foreign material into systems and components, by providing an overview of technical considerations required to develop, implement, and manage a foreign material exclusion program at CNE Cernavoda Unit 1 and 2 Nuclear Power Station. It is also described an example of Foreign Material Intrusion which happened during the 2003 planned maintenance outage at Cernavoda Unit no.1. This paper also defines personnel responsibilities and key nomenclature and a means for evaluating prospective work tasks and activities against standardized criteria, in order to identify the appropriate level of the required FME controls. (author)
Authors:
Urjan, Daniel [1] 
  1. S.N. 'Nuclearelectrica' SA, CNE Cernavoda Nuclear Power Plant, Medgidiei 2 Street, 905200 Cernavoda, Constanta (Romania)
Publication Date:
Jul 01, 2008
Product Type:
Conference
Report Number:
INIS-CH-09-IYNC-2008-118
Resource Relation:
Conference: IYNC 2008: International Youth Nuclear Congress, Interlaken (Switzerland), 21-26 Sep 2008; Other Information: Country of input: France; 8 refs
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; CERNAVODA-1 REACTOR; EQUIPMENT; NUCLEAR POWER PLANTS; OUTAGES; PERSONNEL; REACTOR MAINTENANCE
OSTI ID:
21203102
Research Organizations:
International Youth Nuclear Congress - IYNC (Country Unknown)
Country of Origin:
Switzerland
Language:
English
Other Identifying Numbers:
TRN: CH09V0035073560
Availability:
Available from INIS in electronic form
Submitting Site:
CHN
Size:
15 pages
Announcement Date:
Aug 24, 2009

Citation Formats

Urjan, Daniel. Foreign Material Exclusion Program at CNE Cernavoda Nuclear Generating Station. Switzerland: N. p., 2008. Web.
Urjan, Daniel. Foreign Material Exclusion Program at CNE Cernavoda Nuclear Generating Station. Switzerland.
Urjan, Daniel. 2008. "Foreign Material Exclusion Program at CNE Cernavoda Nuclear Generating Station." Switzerland.
@misc{etde_21203102,
title = {Foreign Material Exclusion Program at CNE Cernavoda Nuclear Generating Station}
author = {Urjan, Daniel}
abstractNote = {In the face of a continuing attention to operations and maintenance costs at nuclear power plants, the future of the industry depends largely upon increasing plant availability and improving operating efficiency. The success in achieving these objectives is dependent upon the success of each plant's equipment maintenance program. Preventing the introduction of foreign materials into a nuclear power plant system or component requires a careful, thoughtful, and professional approach by all site personnel. This paper describes a proactive approach to prevent the introduction of foreign material into systems and components, by providing an overview of technical considerations required to develop, implement, and manage a foreign material exclusion program at CNE Cernavoda Unit 1 and 2 Nuclear Power Station. It is also described an example of Foreign Material Intrusion which happened during the 2003 planned maintenance outage at Cernavoda Unit no.1. This paper also defines personnel responsibilities and key nomenclature and a means for evaluating prospective work tasks and activities against standardized criteria, in order to identify the appropriate level of the required FME controls. (author)}
place = {Switzerland}
year = {2008}
month = {Jul}
}