You need JavaScript to view this

Analysis the mixtures of polyphenyls by gas chromatrogaphie. 1.- Area response for biphenyl and terphenyls relative to triphenylmethane; Analisis de polifenilos por cromatografia de gases 1.- Respuesta relativa del bifenilo y terfenilos respecto al trifenilmetano

Abstract

The relative performances of the thermal conductivity and flame ionization detectors towards triphenylmethane were investigated for each one of the components of biphenyl of biphenyl and terphenyl mixtures. The influence of the concentration of the considered compound as well as the influence derived from the present of all other components on the above-mentioned relative performance were studied. A 2 m long column filled with 50-70 mesh stomacher containing 20% apiezon L was used to carry out the study with the thermal conductivity detector by keeping the column at 300 degree centigree using helium gas as carrier. (Author) 13 refs.
Authors:
Publication Date:
Jul 01, 1966
Product Type:
Technical Report
Report Number:
JEN-168
Subject:
38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEAR CHEMISTRY; POLYPHENYLS; ORGANIC POLYMERS; GAS CHROMATOGRAPHY; GAS ANALYSIS; IONIZATION; IONIZING RADIATIONS; TRIPHENYLMETHANE DYES; BIPHENYL; TERPHENYLS; THERMAL CONDUCTIVITY; HELIUM
OSTI ID:
21157193
Research Organizations:
Junta de Energia Nuclear (JEN), Madrid (Spain)
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
TRN: ES09B0166
Availability:
Commercial reproduction prohibited; OSTI as DE21157193
Submitting Site:
SPN
Size:
22 pages
Announcement Date:
May 16, 2009

Citation Formats

Perez Garcia, M. Analysis the mixtures of polyphenyls by gas chromatrogaphie. 1.- Area response for biphenyl and terphenyls relative to triphenylmethane; Analisis de polifenilos por cromatografia de gases 1.- Respuesta relativa del bifenilo y terfenilos respecto al trifenilmetano. Spain: N. p., 1966. Web.
Perez Garcia, M. Analysis the mixtures of polyphenyls by gas chromatrogaphie. 1.- Area response for biphenyl and terphenyls relative to triphenylmethane; Analisis de polifenilos por cromatografia de gases 1.- Respuesta relativa del bifenilo y terfenilos respecto al trifenilmetano. Spain.
Perez Garcia, M. 1966. "Analysis the mixtures of polyphenyls by gas chromatrogaphie. 1.- Area response for biphenyl and terphenyls relative to triphenylmethane; Analisis de polifenilos por cromatografia de gases 1.- Respuesta relativa del bifenilo y terfenilos respecto al trifenilmetano." Spain.
@misc{etde_21157193,
title = {Analysis the mixtures of polyphenyls by gas chromatrogaphie. 1.- Area response for biphenyl and terphenyls relative to triphenylmethane; Analisis de polifenilos por cromatografia de gases 1.- Respuesta relativa del bifenilo y terfenilos respecto al trifenilmetano}
author = {Perez Garcia, M}
abstractNote = {The relative performances of the thermal conductivity and flame ionization detectors towards triphenylmethane were investigated for each one of the components of biphenyl of biphenyl and terphenyl mixtures. The influence of the concentration of the considered compound as well as the influence derived from the present of all other components on the above-mentioned relative performance were studied. A 2 m long column filled with 50-70 mesh stomacher containing 20% apiezon L was used to carry out the study with the thermal conductivity detector by keeping the column at 300 degree centigree using helium gas as carrier. (Author) 13 refs.}
place = {Spain}
year = {1966}
month = {Jul}
}