Abstract
Tests to know the efficiency of a porous filters cleaning system by blow-back that uses on ejector for each set of simultaneously cleaned filters were carried out. A Calculation method to obtain the optimum ejector for this system was shown, taking n=2, as optimum number of working for the fluidized bed reactors belonging to the Pilot plant of the Materials Division at JEN. That is two filters for each ejector. (Author)
Citation Formats
Sancho Rod, J, and Rodirgo Otero, A.
Cleaning of porous filters in fluidized bed reactors. Use of one ejector for various filters; Limpieza de filtros porosos en reactores lecho fluidizado. Empleo de un eyector para varios filtros.
Spain: N. p.,
1966.
Web.
Sancho Rod, J, & Rodirgo Otero, A.
Cleaning of porous filters in fluidized bed reactors. Use of one ejector for various filters; Limpieza de filtros porosos en reactores lecho fluidizado. Empleo de un eyector para varios filtros.
Spain.
Sancho Rod, J, and Rodirgo Otero, A.
1966.
"Cleaning of porous filters in fluidized bed reactors. Use of one ejector for various filters; Limpieza de filtros porosos en reactores lecho fluidizado. Empleo de un eyector para varios filtros."
Spain.
@misc{etde_21146982,
title = {Cleaning of porous filters in fluidized bed reactors. Use of one ejector for various filters; Limpieza de filtros porosos en reactores lecho fluidizado. Empleo de un eyector para varios filtros}
author = {Sancho Rod, J, and Rodirgo Otero, A}
abstractNote = {Tests to know the efficiency of a porous filters cleaning system by blow-back that uses on ejector for each set of simultaneously cleaned filters were carried out. A Calculation method to obtain the optimum ejector for this system was shown, taking n=2, as optimum number of working for the fluidized bed reactors belonging to the Pilot plant of the Materials Division at JEN. That is two filters for each ejector. (Author)}
place = {Spain}
year = {1966}
month = {Jul}
}
title = {Cleaning of porous filters in fluidized bed reactors. Use of one ejector for various filters; Limpieza de filtros porosos en reactores lecho fluidizado. Empleo de un eyector para varios filtros}
author = {Sancho Rod, J, and Rodirgo Otero, A}
abstractNote = {Tests to know the efficiency of a porous filters cleaning system by blow-back that uses on ejector for each set of simultaneously cleaned filters were carried out. A Calculation method to obtain the optimum ejector for this system was shown, taking n=2, as optimum number of working for the fluidized bed reactors belonging to the Pilot plant of the Materials Division at JEN. That is two filters for each ejector. (Author)}
place = {Spain}
year = {1966}
month = {Jul}
}