You need JavaScript to view this

Eddy current inspection of tubing; Inspeccion de tubos por corrientes de Foucault

Abstract

The Experimental research work carried out to develop a Eddy current testing equipment is described. Search coils with ferrite or air cores were used and the obtained results are discussed. Valuable information was gained from a improved channel in which a direct measure of the defect and the reference signal phase difference is obtained. Artificial defect used to evaluate resolution and sensitivity were produced by electro-machining and mechanical means. Finned SAP tubing was tested in a routine basis with the described equipment and the results plotted. Basic and theoretical considerations on the Eddy current testing technique are given in the last section of this report. (Author)
Publication Date:
Jul 01, 1966
Product Type:
Technical Report
Report Number:
JEN-179
Subject:
36 MATERIALS SCIENCE; EDDY CURRENT TESTING; EQUIPMENT; INFORMATION; EVALUATED DATA; MECHANICAL EFFICIENCY; INSPECTION
OSTI ID:
21135059
Research Organizations:
Junta de Energia Nuclear (JEN), Madrid (Spain)
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
TRN: ES09B0073
Availability:
Commercial reproduction prohibited; OSTI as DE21135059
Submitting Site:
SPN
Size:
24 pages
Announcement Date:
Mar 09, 2009

Citation Formats

Bauza, J L. R., Herrero, J, and Diaz, J. Eddy current inspection of tubing; Inspeccion de tubos por corrientes de Foucault. Spain: N. p., 1966. Web.
Bauza, J L. R., Herrero, J, & Diaz, J. Eddy current inspection of tubing; Inspeccion de tubos por corrientes de Foucault. Spain.
Bauza, J L. R., Herrero, J, and Diaz, J. 1966. "Eddy current inspection of tubing; Inspeccion de tubos por corrientes de Foucault." Spain.
@misc{etde_21135059,
title = {Eddy current inspection of tubing; Inspeccion de tubos por corrientes de Foucault}
author = {Bauza, J L. R., Herrero, J, and Diaz, J}
abstractNote = {The Experimental research work carried out to develop a Eddy current testing equipment is described. Search coils with ferrite or air cores were used and the obtained results are discussed. Valuable information was gained from a improved channel in which a direct measure of the defect and the reference signal phase difference is obtained. Artificial defect used to evaluate resolution and sensitivity were produced by electro-machining and mechanical means. Finned SAP tubing was tested in a routine basis with the described equipment and the results plotted. Basic and theoretical considerations on the Eddy current testing technique are given in the last section of this report. (Author)}
place = {Spain}
year = {1966}
month = {Jul}
}