Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer; Determinacion de masas moleculares medias en refrigerantes nucleares organicos. III-Crioscopia diferencial con termometro termoelectrico

Abstract

The solubility problems raised by some components of the polymeric residue of irradiated polyphenolic coolants, which make it necessary to operate with very small samples, have been solved by means of a differential cryoscopic technique using a thermoelectric thermometer (thermal) as sensitive element. The method is based on the direct measurement of the difference between the freezing points of the investigated solution and of a reference solution whose concentration may be changed at will. The change of {delta} V (mV) versus c(molal) is linear, the equivalent point being determined either analytically or graphically depending on the required accuracy. The method has been tested by measurements on pure polyphenyls, using diphenyl ether as solvent. It has been also applied to the main prospective coolants for the DON reactor. Working with 10{sup 2} molal solutions the accuracy is better than {+-} 2 per cent. (Author) 2 refs.
Publication Date:
Jul 01, 1968
Product Type:
Technical Report
Report Number:
JEN-197
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; ORGANIC COOLANTS; REACTORS; WEIGHT; RESIDUES; MOLECULAR IONS
OSTI ID:
21125900
Research Organizations:
Junta de Energia Nuclear (JEN), Madrid (Spain)
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
TRN: ES09B0047
Availability:
Commercial reproduction prohibited; OSTI as DE21125900
Submitting Site:
SPN
Size:
7 pages
Announcement Date:
Feb 25, 2009

Citation Formats

Becerro, E, and Carreira, M. Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer; Determinacion de masas moleculares medias en refrigerantes nucleares organicos. III-Crioscopia diferencial con termometro termoelectrico. Spain: N. p., 1968. Web.
Becerro, E, & Carreira, M. Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer; Determinacion de masas moleculares medias en refrigerantes nucleares organicos. III-Crioscopia diferencial con termometro termoelectrico. Spain.
Becerro, E, and Carreira, M. 1968. "Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer; Determinacion de masas moleculares medias en refrigerantes nucleares organicos. III-Crioscopia diferencial con termometro termoelectrico." Spain.
@misc{etde_21125900,
title = {Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer; Determinacion de masas moleculares medias en refrigerantes nucleares organicos. III-Crioscopia diferencial con termometro termoelectrico}
author = {Becerro, E, and Carreira, M}
abstractNote = {The solubility problems raised by some components of the polymeric residue of irradiated polyphenolic coolants, which make it necessary to operate with very small samples, have been solved by means of a differential cryoscopic technique using a thermoelectric thermometer (thermal) as sensitive element. The method is based on the direct measurement of the difference between the freezing points of the investigated solution and of a reference solution whose concentration may be changed at will. The change of {delta} V (mV) versus c(molal) is linear, the equivalent point being determined either analytically or graphically depending on the required accuracy. The method has been tested by measurements on pure polyphenyls, using diphenyl ether as solvent. It has been also applied to the main prospective coolants for the DON reactor. Working with 10{sup 2} molal solutions the accuracy is better than {+-} 2 per cent. (Author) 2 refs.}
place = {Spain}
year = {1968}
month = {Jul}
}