You need JavaScript to view this

Radioisotope measurement system; Sistema de medicion de radioisotopos

Abstract

A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [Spanish] Un sistema de instrumentacion instalado en el L.M.R. (Centro Atomico Ezeiza de la CNEA) mide en amplio rango la actividad del decaimiento nuclear de radioisotopos. Permite caracterizar una amplia gama de radioistopos de variados niveles de actividad. Tanto el hardware de medicion como el software de operacion han sido desarrollados y construidos en el Dept. Instrumentacion y Control. El trabajo esboza la conformacion del sistema y su concepto de operacion, describe caracteristicas de disenio, construccion y del tratamiento del error, comenta resultados de ensayos y provee recomendaciones de uso. Pruebas de medicion realizadas empleando diversos nucleidos comprobaron que el  More>>
Authors:
Villanueva Ruibal, Jose [1] 
  1. Comision Nacional de Energia Atomica, Ezeiza (Argentina).Centro Atomico Ezeiza
Publication Date:
Jul 01, 2007
Product Type:
Conference
Report Number:
INIS-AR-C-536
Resource Relation:
Conference: AATN 2007: 34. Annual meeting of the Argentine Association of Nuclear Technology: Nucleo electricity - the solution, AATN 2007: 34. Reunion anual de la Asociacion Argentina de Tecnologia Nuclear (AATN): Nucleoelectricidad: la solucion, Buenos Aires (Argentina), 19-23 Nov 2007; Other Information: 1 tab
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ARGENTINE CNEA; CALIBRATION; COMPUTER CALCULATIONS; ERRORS; IONIZATION CHAMBERS; MEASURING METHODS; RADIOISOTOPES; REACTIVITY METERS
OSTI ID:
21110163
Country of Origin:
Argentina
Language:
Spanish
Other Identifying Numbers:
TRN: AR08C0086117961
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
8 pages
Announcement Date:
Dec 18, 2008

Citation Formats

Villanueva Ruibal, Jose. Radioisotope measurement system; Sistema de medicion de radioisotopos. Argentina: N. p., 2007. Web.
Villanueva Ruibal, Jose. Radioisotope measurement system; Sistema de medicion de radioisotopos. Argentina.
Villanueva Ruibal, Jose. 2007. "Radioisotope measurement system; Sistema de medicion de radioisotopos." Argentina.
@misc{etde_21110163,
title = {Radioisotope measurement system; Sistema de medicion de radioisotopos}
author = {Villanueva Ruibal, Jose}
abstractNote = {A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [Spanish] Un sistema de instrumentacion instalado en el L.M.R. (Centro Atomico Ezeiza de la CNEA) mide en amplio rango la actividad del decaimiento nuclear de radioisotopos. Permite caracterizar una amplia gama de radioistopos de variados niveles de actividad. Tanto el hardware de medicion como el software de operacion han sido desarrollados y construidos en el Dept. Instrumentacion y Control. El trabajo esboza la conformacion del sistema y su concepto de operacion, describe caracteristicas de disenio, construccion y del tratamiento del error, comenta resultados de ensayos y provee recomendaciones de uso. Pruebas de medicion realizadas empleando diversos nucleidos comprobaron que el sistema funciona en forma satisfactoria y su operacion es amigable. (autor)}
place = {Argentina}
year = {2007}
month = {Jul}
}