Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife

Abstract

The Computed Tomography (CT) is an important diagnostic imaging method, widely used. However, in spite of all the advantages and technologic advances within the CT scanners, the tomographic procedures result in high absorbed doses to patients. The main objective of this work was to perform a dosimetric study of CT scanners located at Recife and to evaluate the image quality on CT examinations in these equipment. The volume CT air kerma index (C{sub VOL}) and air kerma length product (P{sub KL,CT}) were estimated. These values were calculated using normalized weighted air kerma indexes in CT standard dosimetry phantoms ({sub n}C{sub W}), supplied by ImPACT group for several CT scanners, and the scan parameters of routine head, routine chest and hi-resolution chest CT exams performed at 20 institutions. The irradiation parameters of 15 adult patients for each CT procedure were registered at six participating centres, at which the phantom from the American College of Radiology (ACR) CT accreditation protocol was used for the image quality measurements. For routine head exams, the C{sub VOL} values varied between 12 and 58 mGy (at the posterior fossa) and 15 to 58 mGy (at the cerebrum) and the P{sub KL,CT}, from 150 to 750 mGy{center_dot}cm.  More>>
Publication Date:
Jul 01, 2008
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-4660
Resource Relation:
Other Information: TH: Diss. (M.Sc.); 64 refs., 53 figs., 37 tabs
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; BIOMEDICAL RADIOGRAPHY; BIOPHYSICS; BRAZIL; CAT SCANNING; DOSE EQUIVALENTS; DOSIMETRY; IMAGE PROCESSING; IMAGE SCANNERS; IMAGES; KERMA; MEASURING METHODS; RADIATION DETECTION; RADIATION DOSES
OSTI ID:
21097003
Research Organizations:
Universidade Federal de Pernambuco (UFPE), Recife (Brazil). Programa de Pos-Graduacao em Tecnologias Energeticas e Nucleares
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR08V3342107635
Availability:
Available from INIS in electronic form
Submitting Site:
BRN
Size:
134 pages
Announcement Date:
Dec 08, 2008

Citation Formats

Andrade, Marcos Ely Almeida. Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife. Brazil: N. p., 2008. Web.
Andrade, Marcos Ely Almeida. Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife. Brazil.
Andrade, Marcos Ely Almeida. 2008. "Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife." Brazil.
@misc{etde_21097003,
title = {Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife}
author = {Andrade, Marcos Ely Almeida}
abstractNote = {The Computed Tomography (CT) is an important diagnostic imaging method, widely used. However, in spite of all the advantages and technologic advances within the CT scanners, the tomographic procedures result in high absorbed doses to patients. The main objective of this work was to perform a dosimetric study of CT scanners located at Recife and to evaluate the image quality on CT examinations in these equipment. The volume CT air kerma index (C{sub VOL}) and air kerma length product (P{sub KL,CT}) were estimated. These values were calculated using normalized weighted air kerma indexes in CT standard dosimetry phantoms ({sub n}C{sub W}), supplied by ImPACT group for several CT scanners, and the scan parameters of routine head, routine chest and hi-resolution chest CT exams performed at 20 institutions. The irradiation parameters of 15 adult patients for each CT procedure were registered at six participating centres, at which the phantom from the American College of Radiology (ACR) CT accreditation protocol was used for the image quality measurements. For routine head exams, the C{sub VOL} values varied between 12 and 58 mGy (at the posterior fossa) and 15 to 58 mGy (at the cerebrum) and the P{sub KL,CT}, from 150 to 750 mGy{center_dot}cm. The C{sub VOL} values for routine chest procedures varied from 3 to 26 mGy and the P{sub KL,CT}, between 120 and 460 mGy{center_dot}cm. In relation to Hi-resolution chest exams, C{sub VOL} values were from 1.0 to 2.7 mGy and the P{sub KL,CT} values varied between 24 and 67 mGy{center_dot}cm. The image quality evaluations results showed that almost all scanners presented at least one inadequacy. One of the equipment presented faults at 70% of the tests. With regard to the image noise, only two scanners presented acceptable results. From these results, it is possible to conclude that the volume CT air kerma index values are lower than the European reference levels. However, the image quality of these CT scanners does not attend the ACR requirements, suggesting the need to implement quality assurance programs at the evaluated institutions. (author)}
place = {Brazil}
year = {2008}
month = {Jul}
}