You need JavaScript to view this

Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation; Determinacao de endotoxina bacteriana (pirogenio) em radiofarmacos pelo metodo de formacao de gel. Validacao

Abstract

Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDA's LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the {sup 131}I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the lyophilized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL{sup -1} (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL{sup -1}, to confirm the labeled sensitivity  More>>
Publication Date:
Jul 01, 2008
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-4639
Resource Relation:
Other Information: TH: Diss. (M.Sc.); 36 refs., 7 figs., 15 tabs., 4 graphs., 3 schemes
Subject:
38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEAR CHEMISTRY; DIAGNOSIS; DRUGS; DYNAMIC FUNCTION STUDIES; ENDOTOXINS; GALLIUM; GALLIUM 67; INFECTIVITY; PHARMACOLOGY; POLYSACCHARIDES; RADIOPHARMACEUTICALS; THALLIUM; THALLIUM 201
OSTI ID:
21096983
Research Organizations:
Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR08V3371107615
Availability:
Available from INIS in electronic form
Submitting Site:
BRN
Size:
77 pages
Announcement Date:
Dec 08, 2008

Citation Formats

Fukumori, Neuza Taeko Okasaki. Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation; Determinacao de endotoxina bacteriana (pirogenio) em radiofarmacos pelo metodo de formacao de gel. Validacao. Brazil: N. p., 2008. Web.
Fukumori, Neuza Taeko Okasaki. Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation; Determinacao de endotoxina bacteriana (pirogenio) em radiofarmacos pelo metodo de formacao de gel. Validacao. Brazil.
Fukumori, Neuza Taeko Okasaki. 2008. "Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation; Determinacao de endotoxina bacteriana (pirogenio) em radiofarmacos pelo metodo de formacao de gel. Validacao." Brazil.
@misc{etde_21096983,
title = {Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation; Determinacao de endotoxina bacteriana (pirogenio) em radiofarmacos pelo metodo de formacao de gel. Validacao}
author = {Fukumori, Neuza Taeko Okasaki}
abstractNote = {Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDA's LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the {sup 131}I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the lyophilized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL{sup -1} (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL{sup -1}, to confirm the labeled sensitivity of the LAL reagent being tested in sterile and non pyrogenic water, in quadruplicate. The same dilution series was performed with the CSE and the product in the 1:100 dilution factor, in three consecutive batches of each radiopharmaceutical. The products {sup 131}I-m-iodobenzylguanidine, Gallium-67, Thallium-201, DTPA, HSA and Colloidal Tin were found compatible with the LAL test at a 1:100 dilution factor. Phytate and GHA showed some interference in the gel clot test. Other techniques to determine endotoxins as the chromogenic (color development) and the turbidimetric test (turbidity development), were also assessed to get valuable quantitative and qualitative information about the endotoxin concentration in samples. (author)}
place = {Brazil}
year = {2008}
month = {Jul}
}