In this work the abilities of intensity-modulated x-ray therapy (IMXT) and intensity-modulated proton therapy (IMPT) to deliver boosts based on theragnostic imaging were assessed. Theragnostic imaging is the use of functional or molecular imaging data for prescribing radiation dose distributions. Distal gradient tracking, an IMPT method designed for the delivery of non-uniform dose distributions, was assessed. Dose prescriptions for a hypoxic region in a head and neck squamous cell carcinoma patient were designed to either uniformly boost the region or redistribute the dose based on positron emission tomography (PET) images of the {sup 61}Cu(II)-diacetyl-bis(N{sub 4}-methylthiosemicarbazone) ({sup 61}Cu-ATSM) hypoxia surrogate. Treatment plans for the prescriptions were created for four different delivery methods: IMXT delivered with step-and-shoot and with helical tomotherapy, and IMPT delivered with spot scanning and distal gradient tracking. IMXT and IMPT delivered comparable dose distributions within the boost region for both uniform and redistributed theragnostic boosts. Normal tissue integral dose was lower by a factor of up to 3 for IMPT relative to the IMXT. For all delivery methods, the mean dose to the nearby organs at risk changed by less than 2 Gy for redistributed versus uniform boosts. The distal gradient tracking method resulted in comparable plans to  More>>
Authors:
Flynn, Ryan T; Bowen, Stephen R; Bentzen, Soeren M; Mackie, T Rockwell; Jeraj, Robert [1] 
  1. Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI 53703 (United States)
Publication Date:
Aug 07, 2008
Product Type:
Journal Article
Resource Relation:
Journal Name: Physics in Medicine and Biology; Journal Volume: 53; Journal Issue: 15; Other Information: PII: S0031-9155(08)74992-3; DOI: 10.1088/0031-9155/53/15/010; Country of input: International Atomic Energy Agency (IAEA)
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ANOXIA; CARCINOMAS; CT-GUIDED RADIOTHERAPY; HEAD; INTEGRAL DOSES; NECK; POSITRON COMPUTED TOMOGRAPHY; PROTON BEAMS; RADIATION DOSE DISTRIBUTIONS
OSTI ID:
21092551
Country of Origin:
United Kingdom
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0031-9155; PHMBA7; TRN: GB08Q0097102602
Availability:
Available from http://dx.doi.org/10.1088/0031-9155/53/15/010;INIS
Submitting Site:
GBN
Size:
page(s) 4153-4167
Announcement Date:
Nov 13, 2008

Citation Formats

Flynn, Ryan T, Bowen, Stephen R, Bentzen, Soeren M, Mackie, T Rockwell, and Jeraj, Robert. Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting. United Kingdom: N. p., 2008. Web. doi:10.1088/0031-9155/53/15/010; COUNTRY OF INPUT: INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA).
Flynn, Ryan T, Bowen, Stephen R, Bentzen, Soeren M, Mackie, T Rockwell, & Jeraj, Robert. Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting. United Kingdom. https://doi.org/10.1088/0031-9155/53/15/010; COUNTRY OF INPUT: INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA)
Flynn, Ryan T, Bowen, Stephen R, Bentzen, Soeren M, Mackie, T Rockwell, and Jeraj, Robert. 2008. "Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting." United Kingdom. https://doi.org/10.1088/0031-9155/53/15/010; COUNTRY OF INPUT: INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA).
@misc{etde_21092551,
title = {Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting}
author = {Flynn, Ryan T, Bowen, Stephen R, Bentzen, Soeren M, Mackie, T Rockwell, and Jeraj, Robert}
abstractNote = {In this work the abilities of intensity-modulated x-ray therapy (IMXT) and intensity-modulated proton therapy (IMPT) to deliver boosts based on theragnostic imaging were assessed. Theragnostic imaging is the use of functional or molecular imaging data for prescribing radiation dose distributions. Distal gradient tracking, an IMPT method designed for the delivery of non-uniform dose distributions, was assessed. Dose prescriptions for a hypoxic region in a head and neck squamous cell carcinoma patient were designed to either uniformly boost the region or redistribute the dose based on positron emission tomography (PET) images of the {sup 61}Cu(II)-diacetyl-bis(N{sub 4}-methylthiosemicarbazone) ({sup 61}Cu-ATSM) hypoxia surrogate. Treatment plans for the prescriptions were created for four different delivery methods: IMXT delivered with step-and-shoot and with helical tomotherapy, and IMPT delivered with spot scanning and distal gradient tracking. IMXT and IMPT delivered comparable dose distributions within the boost region for both uniform and redistributed theragnostic boosts. Normal tissue integral dose was lower by a factor of up to 3 for IMPT relative to the IMXT. For all delivery methods, the mean dose to the nearby organs at risk changed by less than 2 Gy for redistributed versus uniform boosts. The distal gradient tracking method resulted in comparable plans to the spot scanning method while reducing the number of proton beam spots by a factor of over 3.}
doi = {10.1088/0031-9155/53/15/010; COUNTRY OF INPUT: INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA)}
journal = []
issue = {15}
volume = {53}
place = {United Kingdom}
year = {2008}
month = {Aug}
}