Abstract
The design for the construction of a generator 113{sup S}n -113m{sup l}n is described. A systematic assay for de adequate adsorbents has been made, to obtain solutions of high radiochemical purity, as it is required for the radiopharmaceutical preparations. The control of purity is carried on by qualitative and quantitative analysis of the solutions, complemented by radiochemical techniques. The following physico-chemical parameters has been determinate; consecutive equilibrium constants, pH, distribution constants, separation factors and electrophoretic factors. It has been considered the measure of these parameters for the best quality In the preparation of the radiopharmaceutical compounds. (Author) 53 refs.
Citation Formats
Adan, L, and Rebollo, D V.
Generator 113{sup S}n-113m{sup I}n. Study of the most important characteristics in the evaluate composition for the preparation of clinical labelled compounds; Generador de 113{sup S}n- 113m{sup I}n. Estudio de las caracteristicas mas relevantes en la composicion del eluido con miras a la obtencion de compuestos marcados de aplicacion clinica.
Spain: N. p.,
1978.
Web.
Adan, L, & Rebollo, D V.
Generator 113{sup S}n-113m{sup I}n. Study of the most important characteristics in the evaluate composition for the preparation of clinical labelled compounds; Generador de 113{sup S}n- 113m{sup I}n. Estudio de las caracteristicas mas relevantes en la composicion del eluido con miras a la obtencion de compuestos marcados de aplicacion clinica.
Spain.
Adan, L, and Rebollo, D V.
1978.
"Generator 113{sup S}n-113m{sup I}n. Study of the most important characteristics in the evaluate composition for the preparation of clinical labelled compounds; Generador de 113{sup S}n- 113m{sup I}n. Estudio de las caracteristicas mas relevantes en la composicion del eluido con miras a la obtencion de compuestos marcados de aplicacion clinica."
Spain.
@misc{etde_21017440,
title = {Generator 113{sup S}n-113m{sup I}n. Study of the most important characteristics in the evaluate composition for the preparation of clinical labelled compounds; Generador de 113{sup S}n- 113m{sup I}n. Estudio de las caracteristicas mas relevantes en la composicion del eluido con miras a la obtencion de compuestos marcados de aplicacion clinica}
author = {Adan, L, and Rebollo, D V}
abstractNote = {The design for the construction of a generator 113{sup S}n -113m{sup l}n is described. A systematic assay for de adequate adsorbents has been made, to obtain solutions of high radiochemical purity, as it is required for the radiopharmaceutical preparations. The control of purity is carried on by qualitative and quantitative analysis of the solutions, complemented by radiochemical techniques. The following physico-chemical parameters has been determinate; consecutive equilibrium constants, pH, distribution constants, separation factors and electrophoretic factors. It has been considered the measure of these parameters for the best quality In the preparation of the radiopharmaceutical compounds. (Author) 53 refs.}
place = {Spain}
year = {1978}
month = {Jul}
}
title = {Generator 113{sup S}n-113m{sup I}n. Study of the most important characteristics in the evaluate composition for the preparation of clinical labelled compounds; Generador de 113{sup S}n- 113m{sup I}n. Estudio de las caracteristicas mas relevantes en la composicion del eluido con miras a la obtencion de compuestos marcados de aplicacion clinica}
author = {Adan, L, and Rebollo, D V}
abstractNote = {The design for the construction of a generator 113{sup S}n -113m{sup l}n is described. A systematic assay for de adequate adsorbents has been made, to obtain solutions of high radiochemical purity, as it is required for the radiopharmaceutical preparations. The control of purity is carried on by qualitative and quantitative analysis of the solutions, complemented by radiochemical techniques. The following physico-chemical parameters has been determinate; consecutive equilibrium constants, pH, distribution constants, separation factors and electrophoretic factors. It has been considered the measure of these parameters for the best quality In the preparation of the radiopharmaceutical compounds. (Author) 53 refs.}