Quantitative determination of alpha-quartz in airborne dust samples by x-ray diffraction; Determinacion cuantitativa de cuarzo-alfa en polvo atmosferico mediante difraccion de rayos X

Abstract

The quantitative determination by X-ray diffractometry of alpha-quartz In airborne respirable dust samples on silver membrane filters is considered. A cobalt anode X-ray tube Is employed. NiO is used as Internal standard In order to compensate for both the variations of specimen absorption and the effect due to the nonuniformity of the incident X-ray beam and to the incomplete homogeneity on the filters of samples and standards. (Author) 17 refs.
Authors:
Publication Date:
Jul 01, 1982
Product Type:
Technical Report
Report Number:
JEN-514
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; QUARTZ; AIR POLLUTION; X-RAY DIFFRACTION
OSTI ID:
21008420
Research Organizations:
Junta de Energia Nuclear (JEN), Madrid (Spain)
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
TRN: ES08B0159
Availability:
Commercial reproduction prohibited; OSTI as DE21008420
Submitting Site:
SPN
Size:
16 pages
Announcement Date:
Apr 21, 2008

Citation Formats

Bayon, A, and Roca, M. Quantitative determination of alpha-quartz in airborne dust samples by x-ray diffraction; Determinacion cuantitativa de cuarzo-alfa en polvo atmosferico mediante difraccion de rayos X. Spain: N. p., 1982. Web.
Bayon, A, & Roca, M. Quantitative determination of alpha-quartz in airborne dust samples by x-ray diffraction; Determinacion cuantitativa de cuarzo-alfa en polvo atmosferico mediante difraccion de rayos X. Spain.
Bayon, A, and Roca, M. 1982. "Quantitative determination of alpha-quartz in airborne dust samples by x-ray diffraction; Determinacion cuantitativa de cuarzo-alfa en polvo atmosferico mediante difraccion de rayos X." Spain.
@misc{etde_21008420,
title = {Quantitative determination of alpha-quartz in airborne dust samples by x-ray diffraction; Determinacion cuantitativa de cuarzo-alfa en polvo atmosferico mediante difraccion de rayos X}
author = {Bayon, A, and Roca, M}
abstractNote = {The quantitative determination by X-ray diffractometry of alpha-quartz In airborne respirable dust samples on silver membrane filters is considered. A cobalt anode X-ray tube Is employed. NiO is used as Internal standard In order to compensate for both the variations of specimen absorption and the effect due to the nonuniformity of the incident X-ray beam and to the incomplete homogeneity on the filters of samples and standards. (Author) 17 refs.}
place = {Spain}
year = {1982}
month = {Jul}
}