You need JavaScript to view this

Plasma density determination by microwave interferometry .- The 2 mm interferometer of the TJ-1 Tokamak; Determinacion de la densidad de un plasma por interferometria de microondas. El interferometro de 2 mm del Tokamak TJ-1

Abstract

In this paper a description is given of the microwave interferometer used for measuring the plasma electronic density in the TJ-1 Tokamak of Fusion Division of JEN. The principles of the electronic density measurement are discussed in detail, as well as those concerning the determination of density pro files from experimental data. A description of the interferometer used in the TJ-1 Tokamak is given, together with a detailed analysis of the circuits which constitute the measuring chain. The working principles of the klystron reflex and hybrid rings are also presented. (Author) 23 refs.
Publication Date:
Jul 01, 1984
Product Type:
Technical Report
Report Number:
JEN-565
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; PLASMA DENSITY; PLASMA DIAGNOSTICS; INTERFEROMETRY; INTERFEROMETERS; MICROWAVE RADIATION
OSTI ID:
20961218
Research Organizations:
Junta de Energia Nuclear (JEN), Madrid (Spain)
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
TRN: ES07B0592
Availability:
Commercial reproduction prohibited; OSTI as DE20961218
Submitting Site:
SPN
Size:
46 pages
Announcement Date:
Dec 27, 2007

Citation Formats

Martin, R, and Manero, F. Plasma density determination by microwave interferometry .- The 2 mm interferometer of the TJ-1 Tokamak; Determinacion de la densidad de un plasma por interferometria de microondas. El interferometro de 2 mm del Tokamak TJ-1. Spain: N. p., 1984. Web.
Martin, R, & Manero, F. Plasma density determination by microwave interferometry .- The 2 mm interferometer of the TJ-1 Tokamak; Determinacion de la densidad de un plasma por interferometria de microondas. El interferometro de 2 mm del Tokamak TJ-1. Spain.
Martin, R, and Manero, F. 1984. "Plasma density determination by microwave interferometry .- The 2 mm interferometer of the TJ-1 Tokamak; Determinacion de la densidad de un plasma por interferometria de microondas. El interferometro de 2 mm del Tokamak TJ-1." Spain.
@misc{etde_20961218,
title = {Plasma density determination by microwave interferometry .- The 2 mm interferometer of the TJ-1 Tokamak; Determinacion de la densidad de un plasma por interferometria de microondas. El interferometro de 2 mm del Tokamak TJ-1}
author = {Martin, R, and Manero, F}
abstractNote = {In this paper a description is given of the microwave interferometer used for measuring the plasma electronic density in the TJ-1 Tokamak of Fusion Division of JEN. The principles of the electronic density measurement are discussed in detail, as well as those concerning the determination of density pro files from experimental data. A description of the interferometer used in the TJ-1 Tokamak is given, together with a detailed analysis of the circuits which constitute the measuring chain. The working principles of the klystron reflex and hybrid rings are also presented. (Author) 23 refs.}
place = {Spain}
year = {1984}
month = {Jul}
}