You need JavaScript to view this

Adaptation of low-temperature autoradiography to tritium detection by elimination of a parasitic luminescence (1960); Adaptation de l'autoradiographie a basse temperature a la detection du tritium par elimination d'une luminescence parasite (1960)

Abstract

Low-temperature autoradiography, already described by one of the authors, has been applied to the study of the diffusion of tritiated water in the animal organism. In the course of this work some striking disagreements were observed between the measured radioactivity of water in the organs and the relative intensity of blackening of the photographic plate on which they are projected. The cause of these paradoxical images was found in a phenomenon of luminescence, induced by the very soft beta. The application of the low-temperature autoradiography technique to the detection of tritium beta rays therefore involves the use of filters opaque to ultraviolet and visible light, but permitting the autoradiographic recording of radioactivity. (author) [French] Nous avons applique l'autoradiographie a basse temperature decrite par l'un de nous a l'etude de la diffusion de l'eau tritiee dans l'organisme animal. Au cours de ce travail nous avons observe de notables discordances entre la radioactivite mesuree de l'eau des organes et les intensites relatives du noircissement de la plaque photographique sur laquelle ils se projettent. Nous avons trouve la cause de ces images paradoxales dans un phenomene de luminescence provoque par le rayonnement beta tres mou du tritium sur certains milieux biologiques. L'application de  More>>
Authors:
Pellerin, P; Fallot, P; Laine-Boszormenyi,; Serrel, F [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France).Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1960
Product Type:
Technical Report
Report Number:
CEA-R-1675
Resource Relation:
Other Information: 6 refs
Subject:
60 APPLIED LIFE SCIENCES; ABSORPTION; AUTORADIOGRAPHY; BETA PARTICLES; FLUORESCENCE; FREEZING; LABELLED COMPOUNDS; RADIONUCLIDE KINETICS; RATS; TEMPERATURE RANGE 0065-0273 K; TIME DEPENDENCE; TRACER TECHNIQUES; TRITIUM; TRITIUM OXIDES
OSTI ID:
20953764
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR07R1675105045
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
16 pages
Announcement Date:
Dec 27, 2007

Citation Formats

Pellerin, P, Fallot, P, Laine-Boszormenyi,, and Serrel, F. Adaptation of low-temperature autoradiography to tritium detection by elimination of a parasitic luminescence (1960); Adaptation de l'autoradiographie a basse temperature a la detection du tritium par elimination d'une luminescence parasite (1960). France: N. p., 1960. Web.
Pellerin, P, Fallot, P, Laine-Boszormenyi,, & Serrel, F. Adaptation of low-temperature autoradiography to tritium detection by elimination of a parasitic luminescence (1960); Adaptation de l'autoradiographie a basse temperature a la detection du tritium par elimination d'une luminescence parasite (1960). France.
Pellerin, P, Fallot, P, Laine-Boszormenyi,, and Serrel, F. 1960. "Adaptation of low-temperature autoradiography to tritium detection by elimination of a parasitic luminescence (1960); Adaptation de l'autoradiographie a basse temperature a la detection du tritium par elimination d'une luminescence parasite (1960)." France.
@misc{etde_20953764,
title = {Adaptation of low-temperature autoradiography to tritium detection by elimination of a parasitic luminescence (1960); Adaptation de l'autoradiographie a basse temperature a la detection du tritium par elimination d'une luminescence parasite (1960)}
author = {Pellerin, P, Fallot, P, Laine-Boszormenyi,, and Serrel, F}
abstractNote = {Low-temperature autoradiography, already described by one of the authors, has been applied to the study of the diffusion of tritiated water in the animal organism. In the course of this work some striking disagreements were observed between the measured radioactivity of water in the organs and the relative intensity of blackening of the photographic plate on which they are projected. The cause of these paradoxical images was found in a phenomenon of luminescence, induced by the very soft beta. The application of the low-temperature autoradiography technique to the detection of tritium beta rays therefore involves the use of filters opaque to ultraviolet and visible light, but permitting the autoradiographic recording of radioactivity. (author) [French] Nous avons applique l'autoradiographie a basse temperature decrite par l'un de nous a l'etude de la diffusion de l'eau tritiee dans l'organisme animal. Au cours de ce travail nous avons observe de notables discordances entre la radioactivite mesuree de l'eau des organes et les intensites relatives du noircissement de la plaque photographique sur laquelle ils se projettent. Nous avons trouve la cause de ces images paradoxales dans un phenomene de luminescence provoque par le rayonnement beta tres mou du tritium sur certains milieux biologiques. L'application de la technique d'autoradiographie a basse temperature a la detection des rayons beta du tritium implique donc l'emploi de filtres opaques aux lumieres ultraviolette et visible, mais qui permettent l'enregistrement autoradiographique des collections radioactives. (auteur)}
place = {France}
year = {1960}
month = {Jul}
}