You need JavaScript to view this

A Parametric Study of a Constant-Mach-Number MHD Generator with Nuclear Ionization

Abstract

The influence of electrical and gas dynamical parameters on the length, of a linear constant-Mach-number MHD duct has been investigated. The gas has been assumed to be ionized by neutron irradiation in the expansion nozzle preceding the MHD duct. Inside the duct the electron recombination is assumed to be governed, by volume recombination. It is found that there exists a distinct domain from which the parameters must be chosen, pressure and Mach number being the most critical ones. If power densities in the order of magnitude 100 MW/m{sup 3} are desired, high magnetic fields and Mach numbers in the supersonic range are needed. The influence of the variation of critical parameters on the channel length is given as a product of simple functions, each containing one parameter.
Authors:
Publication Date:
Mar 15, 1965
Product Type:
Technical Report
Report Number:
AE-173
Resource Relation:
Other Information: 6 refs., 4 tabs.
Subject:
30 DIRECT ENERGY CONVERSION; 22 GENERAL STUDIES OF NUCLEAR REACTORS; MHD GENERATORS; MACH NUMBER; NEUTRON FLUX; REACTORS
OSTI ID:
20949566
Research Organizations:
AB Atomenergi, Nykoeping (Sweden)
Country of Origin:
Sweden
Language:
English
Other Identifying Numbers:
TRN: SE0708538
Availability:
Commercial reproduction prohibited; OSTI as DE20949566
Submitting Site:
SWDN
Size:
28 pages
Announcement Date:
Dec 17, 2007

Citation Formats

Braun, J. A Parametric Study of a Constant-Mach-Number MHD Generator with Nuclear Ionization. Sweden: N. p., 1965. Web.
Braun, J. A Parametric Study of a Constant-Mach-Number MHD Generator with Nuclear Ionization. Sweden.
Braun, J. 1965. "A Parametric Study of a Constant-Mach-Number MHD Generator with Nuclear Ionization." Sweden.
@misc{etde_20949566,
title = {A Parametric Study of a Constant-Mach-Number MHD Generator with Nuclear Ionization}
author = {Braun, J}
abstractNote = {The influence of electrical and gas dynamical parameters on the length, of a linear constant-Mach-number MHD duct has been investigated. The gas has been assumed to be ionized by neutron irradiation in the expansion nozzle preceding the MHD duct. Inside the duct the electron recombination is assumed to be governed, by volume recombination. It is found that there exists a distinct domain from which the parameters must be chosen, pressure and Mach number being the most critical ones. If power densities in the order of magnitude 100 MW/m{sup 3} are desired, high magnetic fields and Mach numbers in the supersonic range are needed. The influence of the variation of critical parameters on the channel length is given as a product of simple functions, each containing one parameter.}
place = {Sweden}
year = {1965}
month = {Mar}
}