You need JavaScript to view this

Photomultiplier tubes for Low Level Cerenkov Detectors

Abstract

Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a {beta}-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10{sup -12} input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10{sup -12} to 10{sup -9} input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses.
Authors:
Publication Date:
Mar 15, 1965
Product Type:
Technical Report
Report Number:
AE-180
Resource Relation:
Other Information: 10 refs., 5 figs., 4 tabs.
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; PHOTOMULTIPLIERS; CHERENKOV COUNTERS; BETA DETECTION
OSTI ID:
20949560
Research Organizations:
AB Atomenergi, Nykoeping (Sweden)
Country of Origin:
Sweden
Language:
English
Other Identifying Numbers:
TRN: SE0708532
Availability:
Commercial reproduction prohibited; OSTI as DE20949560
Submitting Site:
SWDN
Size:
30 pages
Announcement Date:
Dec 17, 2007

Citation Formats

Strindehag, O. Photomultiplier tubes for Low Level Cerenkov Detectors. Sweden: N. p., 1965. Web.
Strindehag, O. Photomultiplier tubes for Low Level Cerenkov Detectors. Sweden.
Strindehag, O. 1965. "Photomultiplier tubes for Low Level Cerenkov Detectors." Sweden.
@misc{etde_20949560,
title = {Photomultiplier tubes for Low Level Cerenkov Detectors}
author = {Strindehag, O}
abstractNote = {Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a {beta}-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10{sup -12} input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10{sup -12} to 10{sup -9} input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses.}
place = {Sweden}
year = {1965}
month = {Mar}
}