You need JavaScript to view this

Temperature field in the bottom of concrete reactor vessel; Temperaturno polje u podu betonskog reaktorskog suda

Abstract

This paper contains detailed scheme of reactor bottom vessel made of concrete and the results of calculated relevant temperature distribution. Method applied for calculation is described taking into account all relevant factors and assuming that thermal conductivity of concrete is homogeneous and independent of temperature.
Authors:
Jovasevic, V; Tosic, D; Zaric, S; Maksimovic, Lj [1] 
  1. Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)
Publication Date:
Jul 01, 1969
Product Type:
Conference
Report Number:
INIS-RS-1056
Resource Relation:
Conference: ETAN 13. - Conference, Zbornik radova 13. Konferencija za ETAN, Subotica (Yugoslavia), Jun 1969; Other Information: 5 refs, 4 figs
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; CALCULATION METHODS; CONCRETES; R-A REACTOR; REACTOR VESSELS; SPATIAL DISTRIBUTION; TEMPERATURE DISTRIBUTION
OSTI ID:
20929847
Country of Origin:
Serbia
Language:
English
Other Identifying Numbers:
TRN: RS07RB104088461
Availability:
Available from INIS in electronic form; Also available from the Institute of Nuclear Sciences VINCA
Submitting Site:
INIS
Size:
7 pages
Announcement Date:
Nov 13, 2007

Citation Formats

Jovasevic, V, Tosic, D, Zaric, S, and Maksimovic, Lj. Temperature field in the bottom of concrete reactor vessel; Temperaturno polje u podu betonskog reaktorskog suda. Serbia: N. p., 1969. Web.
Jovasevic, V, Tosic, D, Zaric, S, & Maksimovic, Lj. Temperature field in the bottom of concrete reactor vessel; Temperaturno polje u podu betonskog reaktorskog suda. Serbia.
Jovasevic, V, Tosic, D, Zaric, S, and Maksimovic, Lj. 1969. "Temperature field in the bottom of concrete reactor vessel; Temperaturno polje u podu betonskog reaktorskog suda." Serbia.
@misc{etde_20929847,
title = {Temperature field in the bottom of concrete reactor vessel; Temperaturno polje u podu betonskog reaktorskog suda}
author = {Jovasevic, V, Tosic, D, Zaric, S, and Maksimovic, Lj}
abstractNote = {This paper contains detailed scheme of reactor bottom vessel made of concrete and the results of calculated relevant temperature distribution. Method applied for calculation is described taking into account all relevant factors and assuming that thermal conductivity of concrete is homogeneous and independent of temperature.}
place = {Serbia}
year = {1969}
month = {Jul}
}