Abstract
Modifications done on the synchronous generators are related to the emergency power supply system, meaning one of the most important devices responsible for reactor safety. Without reducing the efficiency of the heavy water pumps the improved stability of generators operation was achieved by reducing the possibility of errors and simplifying manipulation. Condensator batteries were improved in order to decrease the leakage currents.
Milosevic, M
[1]
- Institute of Nuclear Sciences Boris Kidric, Reaktor RA, Vinca, Beograd (Serbia and Montenegro)
Citation Formats
Milosevic, M.
Study of the modifications on the synchronous generators, heavy water pumps and condenser batteries of the RA reactor - Annex 17; Prilog 17 - Elaborat o izmenama u semama sinhronih generatora, teskovodnih pumpi i kondenzatorskih baterija reaktora RA.
Serbia and Montenegro: N. p.,
1964.
Web.
Milosevic, M.
Study of the modifications on the synchronous generators, heavy water pumps and condenser batteries of the RA reactor - Annex 17; Prilog 17 - Elaborat o izmenama u semama sinhronih generatora, teskovodnih pumpi i kondenzatorskih baterija reaktora RA.
Serbia and Montenegro.
Milosevic, M.
1964.
"Study of the modifications on the synchronous generators, heavy water pumps and condenser batteries of the RA reactor - Annex 17; Prilog 17 - Elaborat o izmenama u semama sinhronih generatora, teskovodnih pumpi i kondenzatorskih baterija reaktora RA."
Serbia and Montenegro.
@misc{etde_20916379,
title = {Study of the modifications on the synchronous generators, heavy water pumps and condenser batteries of the RA reactor - Annex 17; Prilog 17 - Elaborat o izmenama u semama sinhronih generatora, teskovodnih pumpi i kondenzatorskih baterija reaktora RA}
author = {Milosevic, M}
abstractNote = {Modifications done on the synchronous generators are related to the emergency power supply system, meaning one of the most important devices responsible for reactor safety. Without reducing the efficiency of the heavy water pumps the improved stability of generators operation was achieved by reducing the possibility of errors and simplifying manipulation. Condensator batteries were improved in order to decrease the leakage currents.}
place = {Serbia and Montenegro}
year = {1964}
month = {Dec}
}
title = {Study of the modifications on the synchronous generators, heavy water pumps and condenser batteries of the RA reactor - Annex 17; Prilog 17 - Elaborat o izmenama u semama sinhronih generatora, teskovodnih pumpi i kondenzatorskih baterija reaktora RA}
author = {Milosevic, M}
abstractNote = {Modifications done on the synchronous generators are related to the emergency power supply system, meaning one of the most important devices responsible for reactor safety. Without reducing the efficiency of the heavy water pumps the improved stability of generators operation was achieved by reducing the possibility of errors and simplifying manipulation. Condensator batteries were improved in order to decrease the leakage currents.}
place = {Serbia and Montenegro}
year = {1964}
month = {Dec}
}