You need JavaScript to view this

Oxygen titration in sodium. The mercury method and its use for very low values; Dosage de l'oxygene dans le sodium. La methode au mercure : son utilisation dans le cas de tres faibles teneurs

Abstract

The mercury method for the oxygen titration in sodium has now been known for ten years and is probably the more frequently used. In this text, precision are given to what extent it is valuable when used in microanalysis. Details are given on the apparatus, its manipulation and its calibration. After testing, we have decided to use flame spectroscopy to titrate the sodium hydroxide formed. Discussions are exposed on the errors due to the presence of sodium chloride and calcium. Results are examined from the point of view of their reproducibility and accuracy. If great care is taken, this method allows oxygen titration in sodium even for values below 10 ppm with satisfactory precision. (author) [French] La methode au mercure pour le dosage de l'oxygene dans le sodium est connue depuis une dizaine d'annees, elle est probablement la plus utilisee. Nous avons voulu preciser dans quelle mesure elle etait valable dans le domaine des faibles teneurs avec une precision acceptable. Nous decrivons en detail l'appareil utilise pour l'analyse, le mode operatoire et la methode d'etalonnage. Nos essais nous ont conduit a adopter la spectrographie de flamme pour le dosage de la soude formee, les erreurs introduites par la presence de  More>>
Authors:
Champeix, L; Darras, R; Duflo, J [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1958
Product Type:
Technical Report
Report Number:
CEA-R-835
Resource Relation:
Other Information: 8 refs
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; ACCURACY; CALIBRATION; COMPARATIVE EVALUATIONS; EMISSION SPECTROSCOPY; ERRORS; FILTRATION; INTERFERING ELEMENTS; MERCURY; MICROANALYSIS; OXYGEN; PH VALUE; PRESSURE RANGE MILLI PA; RELIABILITY; SODIUM; SODIUM HYDROXIDES; TITRATION; VACUUM DISTILLATION
OSTI ID:
20889985
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR07R0835054604
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
13 pages
Announcement Date:
Aug 13, 2007

Citation Formats

Champeix, L, Darras, R, and Duflo, J. Oxygen titration in sodium. The mercury method and its use for very low values; Dosage de l'oxygene dans le sodium. La methode au mercure : son utilisation dans le cas de tres faibles teneurs. France: N. p., 1958. Web.
Champeix, L, Darras, R, & Duflo, J. Oxygen titration in sodium. The mercury method and its use for very low values; Dosage de l'oxygene dans le sodium. La methode au mercure : son utilisation dans le cas de tres faibles teneurs. France.
Champeix, L, Darras, R, and Duflo, J. 1958. "Oxygen titration in sodium. The mercury method and its use for very low values; Dosage de l'oxygene dans le sodium. La methode au mercure : son utilisation dans le cas de tres faibles teneurs." France.
@misc{etde_20889985,
title = {Oxygen titration in sodium. The mercury method and its use for very low values; Dosage de l'oxygene dans le sodium. La methode au mercure : son utilisation dans le cas de tres faibles teneurs}
author = {Champeix, L, Darras, R, and Duflo, J}
abstractNote = {The mercury method for the oxygen titration in sodium has now been known for ten years and is probably the more frequently used. In this text, precision are given to what extent it is valuable when used in microanalysis. Details are given on the apparatus, its manipulation and its calibration. After testing, we have decided to use flame spectroscopy to titrate the sodium hydroxide formed. Discussions are exposed on the errors due to the presence of sodium chloride and calcium. Results are examined from the point of view of their reproducibility and accuracy. If great care is taken, this method allows oxygen titration in sodium even for values below 10 ppm with satisfactory precision. (author) [French] La methode au mercure pour le dosage de l'oxygene dans le sodium est connue depuis une dizaine d'annees, elle est probablement la plus utilisee. Nous avons voulu preciser dans quelle mesure elle etait valable dans le domaine des faibles teneurs avec une precision acceptable. Nous decrivons en detail l'appareil utilise pour l'analyse, le mode operatoire et la methode d'etalonnage. Nos essais nous ont conduit a adopter la spectrographie de flamme pour le dosage de la soude formee, les erreurs introduites par la presence de chlorure de sodium et de calcium sont discutes. Les resultats obtenus sont examines du point de vue de la reproductibilite, de la justesse. Moyennant un mode operatoire tres soigne, cette methode permet le dosage de l'oxygene dans le sodium, meme a des teneurs inferieures a 10 ppm avec une precision satisfaisante. (auteur)}
place = {France}
year = {1958}
month = {Jul}
}