The accuracy on the charge measures liberated in a pulse ionization room is limited by the background noise inherent to the used amplifier. Firstly we remind briefly the main features of the signal collected on the electrode collector of the room and the background noise, then the theory of Milatz and Keller. This theory establishes the existence of an absolute limit on the precision of the measures, characteristic of the preamplifier tube and permits its calculation. We define the transient answer of an ideal amplifier allowing effectively this precision. We propose a convenient circuit having this answer and we compare with the usually used circuits. In the case the method of Scherr and Peterson, we show that a supplementary condition render the previous theory insufficient. We calculate the optimum transient response in this case and the value of the limit of precision who ensues. We consider some simple circuits and compare to this limit the precision that they permit to get. (author) [French] La precision sur les mesures de charges liberees dans une chambre d'ionisation a impulsions est limitee par le bruit de fond inherent a l'amplificateur utilise. Nous rappelons brievement tout d'abord les caracteristiques principales du signal recueilli sur  More>>
Authors:
Valladas, G; Leveque, A [1] 
  1. Commissariat a l'Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1952
Product Type:
Technical Report
Report Number:
CEA-R-141
Resource Relation:
Other Information: 12 refs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ACCURACY; BACKGROUND NOISE; ELECTRIC POTENTIAL; FLUCTUATIONS; IONIZATION CHAMBERS; OPTIMIZATION; PREAMPLIFIERS
OSTI ID:
20861727
Research Organizations:
CEA Fontenay-aux-Roses, 92 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R0141024699
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
17 pages
Announcement Date:
Apr 23, 2007

Citation Formats

Valladas, G, and Leveque, A. Background noise in amplifiers of pulse ionization rooms; Le bruit de fond dans les amplificateurs de chambre d'ionisation a impulsions. France: N. p., 1952. Web.
Valladas, G, & Leveque, A. Background noise in amplifiers of pulse ionization rooms; Le bruit de fond dans les amplificateurs de chambre d'ionisation a impulsions. France.
Valladas, G, and Leveque, A. 1952. "Background noise in amplifiers of pulse ionization rooms; Le bruit de fond dans les amplificateurs de chambre d'ionisation a impulsions." France.
@misc{etde_20861727,
title = {Background noise in amplifiers of pulse ionization rooms; Le bruit de fond dans les amplificateurs de chambre d'ionisation a impulsions}
author = {Valladas, G, and Leveque, A}
abstractNote = {The accuracy on the charge measures liberated in a pulse ionization room is limited by the background noise inherent to the used amplifier. Firstly we remind briefly the main features of the signal collected on the electrode collector of the room and the background noise, then the theory of Milatz and Keller. This theory establishes the existence of an absolute limit on the precision of the measures, characteristic of the preamplifier tube and permits its calculation. We define the transient answer of an ideal amplifier allowing effectively this precision. We propose a convenient circuit having this answer and we compare with the usually used circuits. In the case the method of Scherr and Peterson, we show that a supplementary condition render the previous theory insufficient. We calculate the optimum transient response in this case and the value of the limit of precision who ensues. We consider some simple circuits and compare to this limit the precision that they permit to get. (author) [French] La precision sur les mesures de charges liberees dans une chambre d'ionisation a impulsions est limitee par le bruit de fond inherent a l'amplificateur utilise. Nous rappelons brievement tout d'abord les caracteristiques principales du signal recueilli sur l'electrode collectrice de la chambre et du bruit de fond, puis la theorie de Milatz et Keller. Cette theorie etablit l'existence d'une limite absolue sur la precision des mesures, caracteristique du tube preamplificateur, et permet son calcul. Nous definissons la reponse transitoire de l'amplificateur ideal permettant d'attendre effectivement cette precision. Nous proposons un circuit pratique ayant cette reponse et nous lui comparons les circuits habituellement utilises. Dans le cas ou l'on emploie la methode de Scherr et Peterson, nous montrons qu'une condition supplementaire s'introduit rendant la theorie precedente insuffisante. Nous calculons donc la reponse transitoire optimum dans ce cas et la valeur de la precision limite qui en decoule. Nous envisageons quelques circuits simples et comparons a cette limite la precision qu'ils permettent d'obtenir. (auteur)}
place = {France}
year = {1952}
month = {Jul}
}