You need JavaScript to view this

Collimator with compensated filtration: clinical adaptation for recommendation 4f of the EU about the radiation protection in oral dental radiology; Colimador con filtracion compensada: adaptacion clinica para alcanzar la recomendacion 4F de la Union Europea sobre proteccion radiologica al paciente en radiologia odontologica

Abstract

Recent recommendations by the European Union (2004) for performing lateral cranial cephalometry (LCC) state that collimation should be maximized so that only those tissues necessary are irradiated when performing clinical diagnoses, although the fact that many manufacturers do not incorporate these elements in their equipment design has been recognised (recommendations 4f). Aim: the manufacture and utilization of a collimator with a pre-patient compensating filter for LLC which may be used in most extraoraldental radiology units, as well as determining the reduction in the dose of radiation absorbed by more sensitive tissues exposed to said clinical exploration. Making use of mannequins, phantom and craniums, we constructed a collimator with a compensating filter and established the necessary technical, dosimetric and quality specifications for its clinical use. Subsequently, we studied 16 patients referred for cephalometric study, determining the radiation dose (TLDs) in both the patients (crystalline lens, frontal lobe, parotid/submaxillary/thyroid glands and brain) and in the radiographic film, as well as in different parts of the collimator/filter. Al presented we are aiming for its clinical use by carrying out LCC in another 16 patients referred of orthodontic treatment but with the pre-a patient introduction of the tested collimator with the compensating filter as  More>>
Publication Date:
Jul 01, 2006
Product Type:
Journal Article
Resource Relation:
Journal Name: Radioproteccion; Journal Volume: 49; Journal Issue: XIII
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; X-RAY RADIOGRAPHY; RADIATION PROTECTION; RADIATION SOURCES; DOSE RATES; RADIATION DOSES; RADIATION EFFECTS; RADIOLOGY; NUCLEAR MEDICINE
OSTI ID:
20855809
Country of Origin:
Spain
Language:
Spanish
Other Identifying Numbers:
Journal ID: ISSN 1133-1747; RDPREY; TRN: ES07B0071
Submitting Site:
SPN
Size:
page(s) 88-91
Announcement Date:
Apr 16, 2007

Citation Formats

Alcaraz, M, Garcia-Vera, C, Bravo, C La, Morant, J J, Armedo, D Y, and Canteras, M. Collimator with compensated filtration: clinical adaptation for recommendation 4f of the EU about the radiation protection in oral dental radiology; Colimador con filtracion compensada: adaptacion clinica para alcanzar la recomendacion 4F de la Union Europea sobre proteccion radiologica al paciente en radiologia odontologica. Spain: N. p., 2006. Web.
Alcaraz, M, Garcia-Vera, C, Bravo, C La, Morant, J J, Armedo, D Y, & Canteras, M. Collimator with compensated filtration: clinical adaptation for recommendation 4f of the EU about the radiation protection in oral dental radiology; Colimador con filtracion compensada: adaptacion clinica para alcanzar la recomendacion 4F de la Union Europea sobre proteccion radiologica al paciente en radiologia odontologica. Spain.
Alcaraz, M, Garcia-Vera, C, Bravo, C La, Morant, J J, Armedo, D Y, and Canteras, M. 2006. "Collimator with compensated filtration: clinical adaptation for recommendation 4f of the EU about the radiation protection in oral dental radiology; Colimador con filtracion compensada: adaptacion clinica para alcanzar la recomendacion 4F de la Union Europea sobre proteccion radiologica al paciente en radiologia odontologica." Spain.
@misc{etde_20855809,
title = {Collimator with compensated filtration: clinical adaptation for recommendation 4f of the EU about the radiation protection in oral dental radiology; Colimador con filtracion compensada: adaptacion clinica para alcanzar la recomendacion 4F de la Union Europea sobre proteccion radiologica al paciente en radiologia odontologica}
author = {Alcaraz, M, Garcia-Vera, C, Bravo, C La, Morant, J J, Armedo, D Y, and Canteras, M}
abstractNote = {Recent recommendations by the European Union (2004) for performing lateral cranial cephalometry (LCC) state that collimation should be maximized so that only those tissues necessary are irradiated when performing clinical diagnoses, although the fact that many manufacturers do not incorporate these elements in their equipment design has been recognised (recommendations 4f). Aim: the manufacture and utilization of a collimator with a pre-patient compensating filter for LLC which may be used in most extraoraldental radiology units, as well as determining the reduction in the dose of radiation absorbed by more sensitive tissues exposed to said clinical exploration. Making use of mannequins, phantom and craniums, we constructed a collimator with a compensating filter and established the necessary technical, dosimetric and quality specifications for its clinical use. Subsequently, we studied 16 patients referred for cephalometric study, determining the radiation dose (TLDs) in both the patients (crystalline lens, frontal lobe, parotid/submaxillary/thyroid glands and brain) and in the radiographic film, as well as in different parts of the collimator/filter. Al presented we are aiming for its clinical use by carrying out LCC in another 16 patients referred of orthodontic treatment but with the pre-a patient introduction of the tested collimator with the compensating filter as a substitute for the usual technique. The collimation reduced the field or radiation by some 40% and with that, so too the radiated tissues. The compensating filter reduced the dose in tissues by some 34.2. Our collimator has allowed the radiological image to be obtained with only one third the usual radiation dose. The dose reaching the film shies only between 17% less than in the usual technique and didn't alter its diagnostic capacity. A reduction of 61,6% of the dose administered to the patient is achieved by incorporating the collimator and filter to most radiological equipment without the need for renovating or substituting existing apparatus. (Author)}
journal = []
issue = {XIII}
volume = {49}
place = {Spain}
year = {2006}
month = {Jul}
}