Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Vol. V; Album V: Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u VEK reaktora RA

Abstract

Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels includes the following: calculations of CO{sub 2} gas activity, design of the dosimetry control system, review of the changes that should be done in the RA reactor building for installing the independent CO{sub 2} loop, specification of the materials with cost estimation, engineering drawings of the system. Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u vertikalnim eksperimentalnim kanalima reaktora RA sadrzi: proracun aktivnosti gasa CO{sub 2}, idejno resenje sistema dozimetrijske kontrole, pregled izmena koje bi trebalo izvrsiti u zgradi RA u vezi montaze nezavisnog kola CO{sub 2}, specifikaciju materijala sa cenom kostanja i graficku dokumentaciju predprojekta.
Publication Date:
Jul 01, 1964
Product Type:
Technical Report
Report Number:
INIS-CS-0142; RA-103-R1-P3-20
Resource Relation:
Other Information: 3 tabs, 6 figs, 5 refs; 3 tabs, 6 figs, 8 refs; Related Information: In: Independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Task 2.50.05, Nezavisno kolo CO{sub 2} za hladjenje uzoraka ozracivanih u vertikalnim eksperimentalnim kanalima reaktora RA, Zad. 2.50.05, by Stojic, M.; Pavicevic, M, 53 pages.
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; CARBON DIOXIDE; CONTROL SYSTEMS; COOLANT LOOPS; DESIGN; DOSIMETRY; ENGINEERING DRAWINGS; EXPERIMENTAL CHANNELS; IONIZATION CHAMBERS; R-A REACTOR; SPECIFICATIONS
OSTI ID:
20850607
Research Organizations:
Institute of Nuclear Sciences Boris Kidric, Odeljenje za reaktorsku eksperimentalnu tehniku, Vinca, Beograd (Serbia and Montenegro)
Country of Origin:
Serbia and Montenegro
Language:
English
Other Identifying Numbers:
TRN: CS06RA549021084
Availability:
Available from INIS in electronic form; Also available from the Institute of nuclear sciences Vinca
Submitting Site:
INIS
Size:
page(s) 20
Announcement Date:
Apr 02, 2007

Citation Formats

None. Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Vol. V; Album V: Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u VEK reaktora RA. Serbia and Montenegro: N. p., 1964. Web.
None. Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Vol. V; Album V: Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u VEK reaktora RA. Serbia and Montenegro.
None. 1964. "Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Vol. V; Album V: Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u VEK reaktora RA." Serbia and Montenegro.
@misc{etde_20850607,
title = {Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Vol. V; Album V: Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u VEK reaktora RA}
author = {None}
abstractNote = {Design project of the dosimetry control system in the independent CO{sub 2} loop for cooling the samples irradiated in the RA reactor vertical experimental channels includes the following: calculations of CO{sub 2} gas activity, design of the dosimetry control system, review of the changes that should be done in the RA reactor building for installing the independent CO{sub 2} loop, specification of the materials with cost estimation, engineering drawings of the system. Predprojekat sistema dozimetrijske kontrole u nezavisnom kolu CO{sub 2} za hladjenje uzoraka ozracivanih u vertikalnim eksperimentalnim kanalima reaktora RA sadrzi: proracun aktivnosti gasa CO{sub 2}, idejno resenje sistema dozimetrijske kontrole, pregled izmena koje bi trebalo izvrsiti u zgradi RA u vezi montaze nezavisnog kola CO{sub 2}, specifikaciju materijala sa cenom kostanja i graficku dokumentaciju predprojekta.}
place = {Serbia and Montenegro}
year = {1964}
month = {Jul}
}