You need JavaScript to view this

Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau

Abstract

This article concerns a induction flow indicator used at the reactor of Chatillon for the measure of the water debits. It has two sensitivities respectively 2,5 m{sup 3}/h and 10 m{sup 3}/h to the maxima of deviation. The precision of the measures is 1 percent of the maximum of the scale. The equipment is constituted an electronic amplifier followed by a synchronous demodulator functioning to the frequency of the sector. (author) [French] L'article concerne un debitmetre a induction utilise a la Pile de Chatillon pour la mesure des debits d'eau. Il y a deux sensibilites respectivement 2,5 m{sup 3}/h et 10 m{sup 3}/h aux maxima de deviation. La precision des mesures est de 1 pour cent du maximum de l'echelle. L'appareillage est constitue d'un amplificateur electronique suivi d'un demodulateur synchrone fonctionnant a la frequence du secteur. (auteur)
Authors:
Ailloud, J; Chandanson, P [1] 
  1. Commissariat a l'Energie Atomique, Saclay(France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1954
Product Type:
Technical Report
Report Number:
CEA-R-255
Resource Relation:
Other Information: 19 refs
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; AMPLIFIERS; ELECTROMOTIVE FORCE; FLOWMETERS; HEAVY WATER; INDUCTION; REACTOR COOLING SYSTEMS
OSTI ID:
20846016
Research Organizations:
CEA Saclay, 91 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R0255018177
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
15 pages
Announcement Date:
Mar 29, 2007

Citation Formats

Ailloud, J, and Chandanson, P. Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau. France: N. p., 1954. Web.
Ailloud, J, & Chandanson, P. Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau. France.
Ailloud, J, and Chandanson, P. 1954. "Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau." France.
@misc{etde_20846016,
title = {Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau}
author = {Ailloud, J, and Chandanson, P}
abstractNote = {This article concerns a induction flow indicator used at the reactor of Chatillon for the measure of the water debits. It has two sensitivities respectively 2,5 m{sup 3}/h and 10 m{sup 3}/h to the maxima of deviation. The precision of the measures is 1 percent of the maximum of the scale. The equipment is constituted an electronic amplifier followed by a synchronous demodulator functioning to the frequency of the sector. (author) [French] L'article concerne un debitmetre a induction utilise a la Pile de Chatillon pour la mesure des debits d'eau. Il y a deux sensibilites respectivement 2,5 m{sup 3}/h et 10 m{sup 3}/h aux maxima de deviation. La precision des mesures est de 1 pour cent du maximum de l'echelle. L'appareillage est constitue d'un amplificateur electronique suivi d'un demodulateur synchrone fonctionnant a la frequence du secteur. (auteur)}
place = {France}
year = {1954}
month = {Jul}
}