You need JavaScript to view this

Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

Abstract

In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un  More>>
Authors:
Sartory, M [1] 
  1. Commissariat a l'Energie Atomique, Saclay(France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1953
Product Type:
Technical Report
Report Number:
CEA-R-229
Resource Relation:
Other Information: 12 refs
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; ARSENIC 73; COINCIDENCE METHODS; ELECTRON CAPTURE DECAY; GAMMA RADIATION; INTERNAL CONVERSION; K CAPTURE; MEASURING METHODS; NAI DETECTORS; PROPORTIONAL COUNTERS; SELENIUM 75; X RADIATION
OSTI ID:
20846008
Research Organizations:
CEA Saclay, 91 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R0229018169
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
36 pages
Announcement Date:
Apr 02, 2007

Citation Formats

Sartory, M. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations). France: N. p., 1953. Web.
Sartory, M. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations). France.
Sartory, M. 1953. "Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)." France.
@misc{etde_20846008,
title = {Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)}
author = {Sartory, M}
abstractNote = {In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions resultant de chacun des rayonnements etudies. Cette methode, appliquee aux coincidences entre rayons X, a permis d'apporter des renseignements sur le schema de desintegration de l'arsenic 73. De plus, le coefficient de conversion interne d'une transition consecutive a cette desintegration a ete evalue. (auteur)}
place = {France}
year = {1953}
month = {Jul}
}