You need JavaScript to view this

Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant; Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane

Abstract

In this paper the method to calculate the nonsymetric transients in the nuclear power plant is presented. ALMOD 3W2 computer code with steam generator model GEVAP is applied to analyze partial loss of forced reactor coolant flow for NPP Krsko. (author)
Authors:
Bencik, V; [1]  Debrecin, N; Feretic, D; Kozaric, M [2] 
  1. Elektrotehnicki institut 'rade Koncar', Zagreb (Yugoslavia)
  2. Elektrotehnicki fakultet, Zagreb (Yugoslavia)
Publication Date:
Jul 01, 1988
Product Type:
Conference
Report Number:
INIS-RS-0541
Resource Relation:
Conference: 32. Conference - ETRAN '88: Society for Electronics, Telecommunications, Computers, Automation, and Nuclear Engineering, ETAN '88: 32. Konferencija za elektroniku, telekomunikacije, automatiku i nuklearnu tehniku, Sarajevo (Yugoslavia), 6-10 Jun 1988; Other Information: 4 refs., 8 figs
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; A CODES; KRSKO REACTOR; LOSS OF FLOW; PRIMARY COOLANT CIRCUITS; STEAM GENERATORS; TRANSIENTS
OSTI ID:
20840573
Country of Origin:
Serbia
Language:
English
Other Identifying Numbers:
TRN: RS07RA110013843
Availability:
Available from INIS in electronic form; Also available from the Institute of Nuclear Sciences VINCA
Submitting Site:
INIS
Size:
8 pages
Announcement Date:
Mar 26, 2007

Citation Formats

Bencik, V, Debrecin, N, Feretic, D, and Kozaric, M. Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant; Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane. Serbia: N. p., 1988. Web.
Bencik, V, Debrecin, N, Feretic, D, & Kozaric, M. Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant; Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane. Serbia.
Bencik, V, Debrecin, N, Feretic, D, and Kozaric, M. 1988. "Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant; Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane." Serbia.
@misc{etde_20840573,
title = {Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant; Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane}
author = {Bencik, V, Debrecin, N, Feretic, D, and Kozaric, M}
abstractNote = {In this paper the method to calculate the nonsymetric transients in the nuclear power plant is presented. ALMOD 3W2 computer code with steam generator model GEVAP is applied to analyze partial loss of forced reactor coolant flow for NPP Krsko. (author)}
place = {Serbia}
year = {1988}
month = {Jul}
}