Abstract
In this report the classical detection method of the diamagnetic effect by means of a rolled spire on the discharges chamber in the poloidal direction and the difficulties related with this are analyzed. An alternative method that increases considerably the detection sensibility of the diamagnetic effect and that for its simplicity it is quite attractive for its application to the Tokamak Novillo of the ININ is presented. (Author)
Citation Formats
Colunga S, S.
Method of compensation spires for the detection of the diamagnetic effect in a Tokamak; Metodo de espiras de compensacion para la deteccion del efecto diamagnetico en un Tokamak.
Mexico: N. p.,
1990.
Web.
Colunga S, S.
Method of compensation spires for the detection of the diamagnetic effect in a Tokamak; Metodo de espiras de compensacion para la deteccion del efecto diamagnetico en un Tokamak.
Mexico.
Colunga S, S.
1990.
"Method of compensation spires for the detection of the diamagnetic effect in a Tokamak; Metodo de espiras de compensacion para la deteccion del efecto diamagnetico en un Tokamak."
Mexico.
@misc{etde_20826933,
title = {Method of compensation spires for the detection of the diamagnetic effect in a Tokamak; Metodo de espiras de compensacion para la deteccion del efecto diamagnetico en un Tokamak}
author = {Colunga S, S}
abstractNote = {In this report the classical detection method of the diamagnetic effect by means of a rolled spire on the discharges chamber in the poloidal direction and the difficulties related with this are analyzed. An alternative method that increases considerably the detection sensibility of the diamagnetic effect and that for its simplicity it is quite attractive for its application to the Tokamak Novillo of the ININ is presented. (Author)}
place = {Mexico}
year = {1990}
month = {Sep}
}
title = {Method of compensation spires for the detection of the diamagnetic effect in a Tokamak; Metodo de espiras de compensacion para la deteccion del efecto diamagnetico en un Tokamak}
author = {Colunga S, S}
abstractNote = {In this report the classical detection method of the diamagnetic effect by means of a rolled spire on the discharges chamber in the poloidal direction and the difficulties related with this are analyzed. An alternative method that increases considerably the detection sensibility of the diamagnetic effect and that for its simplicity it is quite attractive for its application to the Tokamak Novillo of the ININ is presented. (Author)}
place = {Mexico}
year = {1990}
month = {Sep}
}