You need JavaScript to view this

Optimum input leads for cryogenic apparatus; Optimisation des descentes de courant dans des enceintes cryogeniques

Abstract

The electrical leads used to introduce a current into a cryostat cause a heat influx due to thermal conduction and to Joule heating. It is very important to be able to minimize this flux. Theoretical calculation of optimized leads takes into account the varying heat and electrical conductivities of the leads as well as the heat exchange coefficient with the effluent gas. Practical results have been summarized in different tables which permit for a specific material i.e. copper, aluminium, brass, stainless steel with the intensity and end temperatures being known (i.e. 4,2 or 18,5 deg. K at the cold end; 77,295 or 320 deg. K at the warm end) to deduce the minimum heat flow and the length-cross section ratio of the optimized leads. A general method is indicated, which would allow to solve the same problem for other materials. (author) [French] Les conducteurs electriques assurant la liaison d'appareillages situes dans des cryostats apportent tant par effet Joule que par conductibilite thermique une certaine quantite de chaleur qu'il est tres important de pouvoir minimiser. L'etude theorique de l'optimisation des descentes de courant tient compte des variations des conductibilites thermique et electrique ainsi que de l'influence des echanges avec le gaz.  More>>
Authors:
Der Nigohossian, G [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Feb 15, 1967
Product Type:
Thesis/Dissertation
Report Number:
CEA-R-3167
Resource Relation:
Other Information: TH: Diplome ingenieur CNAM. Specialite: electricite industrielle
Subject:
71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS; CRYOSTATS; ELECTRIC CONDUCTIVITY; ELECTRICAL EQUIPMENT; HEAT FLUX; JOULE HEATING; MINIMIZATION; THERMAL CONDUCTION
OSTI ID:
20818097
Research Organizations:
Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires. Service de physique du solide et de resonnance magnetique
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R3167118226
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
66 pages
Announcement Date:
Jan 04, 2007

Citation Formats

Der Nigohossian, G. Optimum input leads for cryogenic apparatus; Optimisation des descentes de courant dans des enceintes cryogeniques. France: N. p., 1967. Web.
Der Nigohossian, G. Optimum input leads for cryogenic apparatus; Optimisation des descentes de courant dans des enceintes cryogeniques. France.
Der Nigohossian, G. 1967. "Optimum input leads for cryogenic apparatus; Optimisation des descentes de courant dans des enceintes cryogeniques." France.
@misc{etde_20818097,
title = {Optimum input leads for cryogenic apparatus; Optimisation des descentes de courant dans des enceintes cryogeniques}
author = {Der Nigohossian, G}
abstractNote = {The electrical leads used to introduce a current into a cryostat cause a heat influx due to thermal conduction and to Joule heating. It is very important to be able to minimize this flux. Theoretical calculation of optimized leads takes into account the varying heat and electrical conductivities of the leads as well as the heat exchange coefficient with the effluent gas. Practical results have been summarized in different tables which permit for a specific material i.e. copper, aluminium, brass, stainless steel with the intensity and end temperatures being known (i.e. 4,2 or 18,5 deg. K at the cold end; 77,295 or 320 deg. K at the warm end) to deduce the minimum heat flow and the length-cross section ratio of the optimized leads. A general method is indicated, which would allow to solve the same problem for other materials. (author) [French] Les conducteurs electriques assurant la liaison d'appareillages situes dans des cryostats apportent tant par effet Joule que par conductibilite thermique une certaine quantite de chaleur qu'il est tres important de pouvoir minimiser. L'etude theorique de l'optimisation des descentes de courant tient compte des variations des conductibilites thermique et electrique ainsi que de l'influence des echanges avec le gaz. Pratiquement les resultats ont ete resumes dans differents tableaux ce qui permet, pour un materiau donne tel que cuivre, aluminium, laiton, acier inoxydable, connaissant l'intensite et les temperatures d'extremites 4,2 et 18,5 deg. K d'une part, et 77,295 et 330 deg. K d'autre part, de deduire la consommation minimale et le rapport longueur-section d'un conducteur optimise. Une methode generale est indiquee, qui permet de resoudre le probleme pour d'autres materiaux. (auteur)}
place = {France}
year = {1967}
month = {Feb}
}