You need JavaScript to view this

Application of the pulsed neutron technique on the reactors ALIZE - AQUILON (1963); Application de la methode des neutrons pulses sur les piles ALIZE et AQUILON (1963)

Abstract

Different methods of measuring the ratio effective delayed fraction / prompt neutron lifetime, {alpha}{sub c}, are described. According to the classic pulsed neutron technique the negative reactivity due to a localized absorber is given by {rho} / {beta}{sub eff} = {alpha} / {alpha}{sub c} -1 Experiments are reported which show that in this case {alpha}{sub c} can not be considered constant for large reactivities. The absorber element distorts the flux in the system, increasing the importance of the reflector. An application of the pulsed neutron method to the measurement of critical distributed boron concentrations of various absorber elements is described. Less time is required than for the usual super-critical techniques, and the experimental analysis is simplified. It is interesting to note that the results are not influenced by the spectral sensitivity of the control element. A modified pulsed neutron method has been tried out. This procedure was used to determine by measurements at sub-critical the critical water level of uranium-heavy water lattices with a high precision. (author) [French] Differents modes operatoires pour definir la valeur du rapport pourcentage effectif de neutrons retardes / temps de vie, {alpha}{sub c}, sont exposes. La methode classique par neutrons pulses definit l'anti-reactivite d'un element  More>>
Authors:
Jacquemart, R [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1963
Product Type:
Technical Report
Report Number:
CEA-R-2376
Resource Relation:
Other Information: 25 refs
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; AQUILON REACTOR; CRITICAL MASS; CRITICALITY; DELAYED NEUTRON FRACTION; NEUTRON ABSORBERS; NEUTRON REFLECTORS; PULSED NEUTRON TECHNIQUES; REACTIVITY; REACTOR KINETICS
OSTI ID:
20818058
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R2376118187
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
37 pages
Announcement Date:
Jan 04, 2007

Citation Formats

Jacquemart, R. Application of the pulsed neutron technique on the reactors ALIZE - AQUILON (1963); Application de la methode des neutrons pulses sur les piles ALIZE et AQUILON (1963). France: N. p., 1963. Web.
Jacquemart, R. Application of the pulsed neutron technique on the reactors ALIZE - AQUILON (1963); Application de la methode des neutrons pulses sur les piles ALIZE et AQUILON (1963). France.
Jacquemart, R. 1963. "Application of the pulsed neutron technique on the reactors ALIZE - AQUILON (1963); Application de la methode des neutrons pulses sur les piles ALIZE et AQUILON (1963)." France.
@misc{etde_20818058,
title = {Application of the pulsed neutron technique on the reactors ALIZE - AQUILON (1963); Application de la methode des neutrons pulses sur les piles ALIZE et AQUILON (1963)}
author = {Jacquemart, R}
abstractNote = {Different methods of measuring the ratio effective delayed fraction / prompt neutron lifetime, {alpha}{sub c}, are described. According to the classic pulsed neutron technique the negative reactivity due to a localized absorber is given by {rho} / {beta}{sub eff} = {alpha} / {alpha}{sub c} -1 Experiments are reported which show that in this case {alpha}{sub c} can not be considered constant for large reactivities. The absorber element distorts the flux in the system, increasing the importance of the reflector. An application of the pulsed neutron method to the measurement of critical distributed boron concentrations of various absorber elements is described. Less time is required than for the usual super-critical techniques, and the experimental analysis is simplified. It is interesting to note that the results are not influenced by the spectral sensitivity of the control element. A modified pulsed neutron method has been tried out. This procedure was used to determine by measurements at sub-critical the critical water level of uranium-heavy water lattices with a high precision. (author) [French] Differents modes operatoires pour definir la valeur du rapport pourcentage effectif de neutrons retardes / temps de vie, {alpha}{sub c}, sont exposes. La methode classique par neutrons pulses definit l'anti-reactivite d'un element absorbant a partir de la relation: {rho} / {beta}{sub eff} {alpha} / {alpha}{sub c} -1 Les manipulations effectuees montrent qu'on ne peut considerer dans ce cas {alpha}{sub c} constant pour de tres grandes anti-reactivites. L'absorbant introduit dans la pile deforme le flux et augmente l'importance du reflecteur. Une application de la methode des neutrons pulses pour mesurer le titre critique en mg de B/l de divers absorbants est signalee. Les operations sont effectuees en regime sous-critique avec un certain gain de temps et une grande facilite de depouillement. Il est interessant de noter que les resultats ne sont pas affectes par la sensibilite spectrale des absorbants. Une methode modifiee utilisant la technique des neutrons pulses a ete experimentee. Les experiences sous-critiques ont permis de definir avec une bonne precision des tailles critiques de reseaux uranium-eau lourde. (auteur)}
place = {France}
year = {1963}
month = {Jul}
}