After outlining the present state of knowledge concerning the determination of doses absorbed by external irradiation for various types of radiation, the author gives figures for the comparative sensitivity of common detectors. He then defines the criteria which have to be considered for the choice of the sensitive medium and of the nature and the thickness of the detector walls. Considered very generally, the detection assembly intended for measuring the dose absorbed at a given point in the organism must be designed with a view to giving the same overall interactions with the radiation considered as those occurring in the organism. (author) [French] Apres avoir precise l'etat de nos connaissances generales actuelles concernant la determination des doses absorbees par irradiation externe pour les divers rayonnements, l'auteur indique la sensibilite comparee des detecteurs usuels. Il definit ensuite les criteres qui doivent etre pris en consideration pour le choix du milieu sensible, de la nature et de l'epaisseur de la paroi des detecteurs. D'une maniere tres generale, l'ensemble de detection destine a mesurer une dose absorbee en un point donne de l'organisme doit etre concu en vue de presenter les memes interactions globales avec le rayonnement etudie que celles mises en jeu  More>>
Authors:
Joffre, H [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1963
Product Type:
Technical Report
Report Number:
CEA-R-2281
Resource Relation:
Other Information: 8 refs
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; BETA DOSIMETRY; DOSE EQUIVALENTS; EXTERNAL IRRADIATION; GAMMA DOSIMETRY; PERSONNEL DOSIMETRY; RADIATION ABSORPTION ANALYSIS; RADIATION DOSES; RADIATION MONITORS; TISSUE-EQUIVALENT MATERIALS; X-RAY DOSIMETRY
OSTI ID:
20808535
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R2281110040
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
48 pages
Announcement Date:
Dec 23, 2006

Citation Formats

Joffre, H. Consideration of the problems of the separate measurement of {beta}, {gamma} and X radiation; Considerations sur les problemes de la dosimetrie individuelle des radiations {beta}, {gamma}, X. France: N. p., 1963. Web.
Joffre, H. Consideration of the problems of the separate measurement of {beta}, {gamma} and X radiation; Considerations sur les problemes de la dosimetrie individuelle des radiations {beta}, {gamma}, X. France.
Joffre, H. 1963. "Consideration of the problems of the separate measurement of {beta}, {gamma} and X radiation; Considerations sur les problemes de la dosimetrie individuelle des radiations {beta}, {gamma}, X." France.
@misc{etde_20808535,
title = {Consideration of the problems of the separate measurement of {beta}, {gamma} and X radiation; Considerations sur les problemes de la dosimetrie individuelle des radiations {beta}, {gamma}, X}
author = {Joffre, H}
abstractNote = {After outlining the present state of knowledge concerning the determination of doses absorbed by external irradiation for various types of radiation, the author gives figures for the comparative sensitivity of common detectors. He then defines the criteria which have to be considered for the choice of the sensitive medium and of the nature and the thickness of the detector walls. Considered very generally, the detection assembly intended for measuring the dose absorbed at a given point in the organism must be designed with a view to giving the same overall interactions with the radiation considered as those occurring in the organism. (author) [French] Apres avoir precise l'etat de nos connaissances generales actuelles concernant la determination des doses absorbees par irradiation externe pour les divers rayonnements, l'auteur indique la sensibilite comparee des detecteurs usuels. Il definit ensuite les criteres qui doivent etre pris en consideration pour le choix du milieu sensible, de la nature et de l'epaisseur de la paroi des detecteurs. D'une maniere tres generale, l'ensemble de detection destine a mesurer une dose absorbee en un point donne de l'organisme doit etre concu en vue de presenter les memes interactions globales avec le rayonnement etudie que celles mises en jeu dans l'organisme. (auteur)}
place = {France}
year = {1963}
month = {Jul}
}