Abstract
For measuring the temperature gradients between the inlet and outlet water in the reactor channels with VISA-2 irradiation capsules, the previously used platinum resistance thermometers are replaced by thermocouples. This document includes detailed instructions for using these new instruments for measuring the temperature gradients in each reactor channel during experiments. [Serbo-Croat] Za merenje razlike temperature ulazne i izlazne vode u tehnoloskim kanalima sa kapsulama VISA-2, nalaze se umesto dosadasnjih platinskim otpornih termometara, termoparovi koji mere razliku temperature po svakom kanalu. Ovaj dokument sadrzi detaljna uputstva za koriscenje novih instrumenata za merenje razlike temperature tokom eksperimenta.
Pavicevic, M;
Nikolic, M
[1]
- Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)
Citation Formats
Pavicevic, M, and Nikolic, M.
Additional instructions related to VISA-2 experiment for instrumentation personnel on duty; Dodatak instrukcijama za dezurne instrumentatore u vezi eksperimenta VISA-2.
Serbia and Montenegro: N. p.,
1963.
Web.
Pavicevic, M, & Nikolic, M.
Additional instructions related to VISA-2 experiment for instrumentation personnel on duty; Dodatak instrukcijama za dezurne instrumentatore u vezi eksperimenta VISA-2.
Serbia and Montenegro.
Pavicevic, M, and Nikolic, M.
1963.
"Additional instructions related to VISA-2 experiment for instrumentation personnel on duty; Dodatak instrukcijama za dezurne instrumentatore u vezi eksperimenta VISA-2."
Serbia and Montenegro.
@misc{etde_20804981,
title = {Additional instructions related to VISA-2 experiment for instrumentation personnel on duty; Dodatak instrukcijama za dezurne instrumentatore u vezi eksperimenta VISA-2}
author = {Pavicevic, M, and Nikolic, M}
abstractNote = {For measuring the temperature gradients between the inlet and outlet water in the reactor channels with VISA-2 irradiation capsules, the previously used platinum resistance thermometers are replaced by thermocouples. This document includes detailed instructions for using these new instruments for measuring the temperature gradients in each reactor channel during experiments. [Serbo-Croat] Za merenje razlike temperature ulazne i izlazne vode u tehnoloskim kanalima sa kapsulama VISA-2, nalaze se umesto dosadasnjih platinskim otpornih termometara, termoparovi koji mere razliku temperature po svakom kanalu. Ovaj dokument sadrzi detaljna uputstva za koriscenje novih instrumenata za merenje razlike temperature tokom eksperimenta.}
place = {Serbia and Montenegro}
year = {1963}
month = {Jan}
}
title = {Additional instructions related to VISA-2 experiment for instrumentation personnel on duty; Dodatak instrukcijama za dezurne instrumentatore u vezi eksperimenta VISA-2}
author = {Pavicevic, M, and Nikolic, M}
abstractNote = {For measuring the temperature gradients between the inlet and outlet water in the reactor channels with VISA-2 irradiation capsules, the previously used platinum resistance thermometers are replaced by thermocouples. This document includes detailed instructions for using these new instruments for measuring the temperature gradients in each reactor channel during experiments. [Serbo-Croat] Za merenje razlike temperature ulazne i izlazne vode u tehnoloskim kanalima sa kapsulama VISA-2, nalaze se umesto dosadasnjih platinskim otpornih termometara, termoparovi koji mere razliku temperature po svakom kanalu. Ovaj dokument sadrzi detaljna uputstva za koriscenje novih instrumenata za merenje razlike temperature tokom eksperimenta.}
place = {Serbia and Montenegro}
year = {1963}
month = {Jan}
}