You need JavaScript to view this

Evaluation of microleakage occurred in class V restoration prepared with Er:YAG laser and also with high speed, restored using composite; Avaliacao da microinfiltracao em cavidades classe V preparada com laser de Er:YAG ou alta rotacao, jateadas ou nao com bicarbonato de sodio e restauradas com resina composta

Abstract

The microleakage is one of the great problems found in restoring dentistry. In spite of adhesive system evolution, several materials have been studied intending to minimize or to eliminate the microleakage occurred between the tooth and restorative material. The objective of this in vitro study was to evaluate and compare the marginal microleakage in class V cavities prepared by Er:YAG laser or high speed and restored with composite resin. One of the groups received the sodium bicarbonate jet while the other group have not received. Twenty teeth third extracted molars were sectioned in the sense medial-distal being obtained forty samples that were divided in four groups: Group I (G1): prepared with Er:YAG laser (2940 nm), E= 350 mJ/p, F=2 Hz, fluency of 112,5 J/cm{sup 2}. Preparing occlusion margin slice with 250 mJ/p, F=2 Hz, fluency of 80,3 J/cm{sup 2}. The prepared total area was irradiated with E=80 mJ/p, F=2 Hz and fluency of 25,75 J/cm{sup 2}. Every prepared area was finally submitted to sodium bicarbonate jet. Group 2 (G2): it was employed the same parameters used on group 1, except the sodium carbonate jet application. Group 3 (G3): the cavities' prepare were executed with high speed rotation using diamond cylindrical  More>>
Publication Date:
Jul 01, 2002
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-4000
Resource Relation:
Other Information: TH: Dissertacao (M.Sc.); 115 refs., 38 figs., 8 tabs
Subject:
63 RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS; BIOLOGICAL RADIATION EFFECTS; DENTIN; DENTISTRY; ENAMELS; ERBIUM; IN VITRO; LASER RADIATION; LASERS; RESINS; SCANNING ELECTRON MICROSCOPY; TEETH
OSTI ID:
20767273
Research Organizations:
Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR0645279073875
Availability:
Available from INIS in electronic form
Submitting Site:
BRN
Size:
95 pages
Announcement Date:
Sep 25, 2006

Citation Formats

Junqueira, Angelo Maercio Finochio. Evaluation of microleakage occurred in class V restoration prepared with Er:YAG laser and also with high speed, restored using composite; Avaliacao da microinfiltracao em cavidades classe V preparada com laser de Er:YAG ou alta rotacao, jateadas ou nao com bicarbonato de sodio e restauradas com resina composta. Brazil: N. p., 2002. Web.
Junqueira, Angelo Maercio Finochio. Evaluation of microleakage occurred in class V restoration prepared with Er:YAG laser and also with high speed, restored using composite; Avaliacao da microinfiltracao em cavidades classe V preparada com laser de Er:YAG ou alta rotacao, jateadas ou nao com bicarbonato de sodio e restauradas com resina composta. Brazil.
Junqueira, Angelo Maercio Finochio. 2002. "Evaluation of microleakage occurred in class V restoration prepared with Er:YAG laser and also with high speed, restored using composite; Avaliacao da microinfiltracao em cavidades classe V preparada com laser de Er:YAG ou alta rotacao, jateadas ou nao com bicarbonato de sodio e restauradas com resina composta." Brazil.
@misc{etde_20767273,
title = {Evaluation of microleakage occurred in class V restoration prepared with Er:YAG laser and also with high speed, restored using composite; Avaliacao da microinfiltracao em cavidades classe V preparada com laser de Er:YAG ou alta rotacao, jateadas ou nao com bicarbonato de sodio e restauradas com resina composta}
author = {Junqueira, Angelo Maercio Finochio}
abstractNote = {The microleakage is one of the great problems found in restoring dentistry. In spite of adhesive system evolution, several materials have been studied intending to minimize or to eliminate the microleakage occurred between the tooth and restorative material. The objective of this in vitro study was to evaluate and compare the marginal microleakage in class V cavities prepared by Er:YAG laser or high speed and restored with composite resin. One of the groups received the sodium bicarbonate jet while the other group have not received. Twenty teeth third extracted molars were sectioned in the sense medial-distal being obtained forty samples that were divided in four groups: Group I (G1): prepared with Er:YAG laser (2940 nm), E= 350 mJ/p, F=2 Hz, fluency of 112,5 J/cm{sup 2}. Preparing occlusion margin slice with 250 mJ/p, F=2 Hz, fluency of 80,3 J/cm{sup 2}. The prepared total area was irradiated with E=80 mJ/p, F=2 Hz and fluency of 25,75 J/cm{sup 2}. Every prepared area was finally submitted to sodium bicarbonate jet. Group 2 (G2): it was employed the same parameters used on group 1, except the sodium carbonate jet application. Group 3 (G3): the cavities' prepare were executed with high speed rotation using diamond cylindrical point. The slice confection has been made with the same point with 45 degrees inclined, utilizing also the sodium carbonate jet in all prepared area. Group 4 (G4): it was executed similarly prepared to group 3, without the sodium bicarbonate jet. In all the groups the cavities were washed with water spray and drought with air jet. Dentin and enamel surfaces have been conditioned with phosphoric acid at 35%. All the samples of all groups were restored using the single bond system adhesive and composite resin Z250, kept at 37 deg C in stove during 24 hours, thermally stressed, immersed in silver nitrate solution at 50% for 24 hours while kept in darkness. The specimens were soaked in photo developing solution and exposed to fluorescent light for 6 hours. These teeth have been sectioning and evaluated through stereomicroscopy. The results were analyzed under statistical Kruskal-Wallis test. In conclusion, in the gingival margin, the microleakage obtained on group G1 showed be lesser then that found in the other groups G3 and G4, being statistically significant this difference. (au0010th.}
place = {Brazil}
year = {2002}
month = {Jul}
}