You need JavaScript to view this

Use of the calorimeter in the dosimetry for electron accelerators; Uso del calorimetro en la dosimetria para aceleradores de electrones

Abstract

The measure of different radiation types, with specific dosemeters, requires that the absorbed dose should be measured with accuracy by some common standard. The existent problem around the dosimetry of accelerated electrons has forced to the development of diverse detector types that after having analyzed the characteristics; dependability and reproducibility are used as dosemeters. Recently the calorimeters have been developed, with the purpose of carrying out dosimetry for electron accelerators. The RISO laboratory in Denmark, in it 10 MeV accelerator had been used for the dosimetry those water calorimeters, later on, using the principle of the water calorimeter, it was designing one similar, for the accelerator of 400 keV. Recently manufactured simple calorimeters of graphite have been used, which can be used in both accelerators of 10 MeV and 400 keV. (Author)
Authors:
Publication Date:
Feb 15, 1991
Product Type:
Technical Report
Report Number:
IA-91-301; INIS-MX-RI-0113
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CALORIMETERS; DESIGN; DIAGRAMS; DOSIMETRY; ELECTRON BEAMS; GRAPHITE; LINEAR ACCELERATORS; RADIATION DOSES; SPECIFIC HEAT; TEMPERATURE DEPENDENCE
OSTI ID:
20764686
Research Organizations:
Instituto Nacional de Investigaciones Nucleares, Ocoyoacac (Mexico)
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
TRN: MX0600157070739
Availability:
Available from INIS in electronic form
Submitting Site:
MXN
Size:
14 pages
Announcement Date:
Sep 06, 2006

Citation Formats

Chavez B, A. Use of the calorimeter in the dosimetry for electron accelerators; Uso del calorimetro en la dosimetria para aceleradores de electrones. Mexico: N. p., 1991. Web.
Chavez B, A. Use of the calorimeter in the dosimetry for electron accelerators; Uso del calorimetro en la dosimetria para aceleradores de electrones. Mexico.
Chavez B, A. 1991. "Use of the calorimeter in the dosimetry for electron accelerators; Uso del calorimetro en la dosimetria para aceleradores de electrones." Mexico.
@misc{etde_20764686,
title = {Use of the calorimeter in the dosimetry for electron accelerators; Uso del calorimetro en la dosimetria para aceleradores de electrones}
author = {Chavez B, A}
abstractNote = {The measure of different radiation types, with specific dosemeters, requires that the absorbed dose should be measured with accuracy by some common standard. The existent problem around the dosimetry of accelerated electrons has forced to the development of diverse detector types that after having analyzed the characteristics; dependability and reproducibility are used as dosemeters. Recently the calorimeters have been developed, with the purpose of carrying out dosimetry for electron accelerators. The RISO laboratory in Denmark, in it 10 MeV accelerator had been used for the dosimetry those water calorimeters, later on, using the principle of the water calorimeter, it was designing one similar, for the accelerator of 400 keV. Recently manufactured simple calorimeters of graphite have been used, which can be used in both accelerators of 10 MeV and 400 keV. (Author)}
place = {Mexico}
year = {1991}
month = {Feb}
}