You need JavaScript to view this

Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography; Determinacao de parametros geometricos estruturais de espumas ceramicas industriais por transmissao de raios gama e microtomografia de raios X

Abstract

In this work, the gamma rays transmission and X-rays microtomography techniques are used for the evaluation of the porosity and the pore size distribution of SiC ceramic foams. It was also accomplished the three-dimensional images after the determination of samples geometric parameters. The geometric parameters were obtained by two-dimensional images analyses, generated by a Microfocus system, with a CCD camera, an images intensifier, a X-rays tube and an automatic system for rotation of the sample. The spatial resolution of the images was about 32 {mu}m. In the gamma rays transmission methodology, a Nal(Tl) scintillation detector, an {sup 241}Am (59.53 keV, 100 mCi) radioactive source and an automatic X-Z micrometric table was used. The analyzed samples had pores density of 30, 45, 60, 80 and 100 ppi (pores per inch). The gamma rays transmission technique was accurate to supply the porosity of the samples, which ranged about 90% and was in agreement with the values supplied by manufacturer of the foams. The 30 and 45 ppi samples analyzed by X-rays microtomography showed porosity results that agree with the average porosity supplied by the manufacturer. In other hand, the 60, 80 and 100 ppi samples systematically showed average porosity about 4%, lower  More>>
Publication Date:
Jul 01, 2005
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-4008
Resource Relation:
Other Information: TH: Dissertacao (M.Sc.); 25 refs., 69 figs., 8 tabs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; AMERICIUM 241; EXPERIMENTAL DATA; FOAMS; GAMMA RADIATION; I CODES; NAI DETECTORS; NONDESTRUCTIVE ANALYSIS; PHOTON TRANSMISSION SCANNING; PORE STRUCTURE; POROSITY; SILICON CARBIDES; SIZE; SPATIAL RESOLUTION; THREE-DIMENSIONAL CALCULATIONS; TOMOGRAPHY; TWO-DIMENSIONAL CALCULATIONS
OSTI ID:
20761963
Research Organizations:
Universidade Estadual de Londrina, PR (Brazil). Curso de Pos-graduacao em Fisica
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR0645285069015
Availability:
Available from INIS in electronic form
Submitting Site:
BRN
Size:
127 pages
Announcement Date:
Sep 06, 2006

Citation Formats

Rocha, Wilson Roberto Dejato da. Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography; Determinacao de parametros geometricos estruturais de espumas ceramicas industriais por transmissao de raios gama e microtomografia de raios X. Brazil: N. p., 2005. Web.
Rocha, Wilson Roberto Dejato da. Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography; Determinacao de parametros geometricos estruturais de espumas ceramicas industriais por transmissao de raios gama e microtomografia de raios X. Brazil.
Rocha, Wilson Roberto Dejato da. 2005. "Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography; Determinacao de parametros geometricos estruturais de espumas ceramicas industriais por transmissao de raios gama e microtomografia de raios X." Brazil.
@misc{etde_20761963,
title = {Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography; Determinacao de parametros geometricos estruturais de espumas ceramicas industriais por transmissao de raios gama e microtomografia de raios X}
author = {Rocha, Wilson Roberto Dejato da}
abstractNote = {In this work, the gamma rays transmission and X-rays microtomography techniques are used for the evaluation of the porosity and the pore size distribution of SiC ceramic foams. It was also accomplished the three-dimensional images after the determination of samples geometric parameters. The geometric parameters were obtained by two-dimensional images analyses, generated by a Microfocus system, with a CCD camera, an images intensifier, a X-rays tube and an automatic system for rotation of the sample. The spatial resolution of the images was about 32 {mu}m. In the gamma rays transmission methodology, a Nal(Tl) scintillation detector, an {sup 241}Am (59.53 keV, 100 mCi) radioactive source and an automatic X-Z micrometric table was used. The analyzed samples had pores density of 30, 45, 60, 80 and 100 ppi (pores per inch). The gamma rays transmission technique was accurate to supply the porosity of the samples, which ranged about 90% and was in agreement with the values supplied by manufacturer of the foams. The 30 and 45 ppi samples analyzed by X-rays microtomography showed porosity results that agree with the average porosity supplied by the manufacturer. In other hand, the 60, 80 and 100 ppi samples systematically showed average porosity about 4%, lower than the average of the manufacturer. The pore size distributions found through the software IMAGO show the presence of smaller pores than those nominated by the manufacturer. The 30 ppi samples had voids inside the solid material of the ceramic foams structure. Gaussian truncated method, used in the three-dimensional reconstruction, was not able to take into the account the voids inside the solid matrix. (author)}
place = {Brazil}
year = {2005}
month = {Jul}
}