Measurements of radiation level were done in 7 points of the heavy water system and distillation system. Measuring results shown in this report show that the radiation intensity was highest on the heat exchangers and lowest on the incoming pipe at the heavy water distillation system. [Serbo-Croat] Merenja intenziteta zracenja vrsena su u 7 tacaka teskovodnog sistema i sistema destilacije. Rezultati merenja prikazani u ovom izvestaju pokazuju da je intenzitet zracenja najveci na toploizmenjivacima, a najmanji na dovodnoj cevi teske vode na destilaciji.
Authors:
Zecevic, V [1] 
  1. Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)
Publication Date:
Dec 15, 1963
Product Type:
Technical Report
Report Number:
INIS-CS-0096; RA-214/R3/P3/56/08
Resource Relation:
Other Information: 9 figs; 6 tabs, 6 figs, 7 refs; Related Information: In: Heavy water pumps, Pumpe D{sub 2}O, by Zecevic, V.; Nikolic, M, 149 pages.
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; ACTIVITY LEVELS; DISTILLATION; HEAVY WATER; R-A REACTOR; RADIATION MONITORING; REACTOR COOLING SYSTEMS
OSTI ID:
20743614
Research Organizations:
Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)
Country of Origin:
Serbia and Montenegro
Language:
English
Other Identifying Numbers:
TRN: CS06RA464052914
Availability:
Available from INIS in electronic form; Also available from the Institute of nuclear sciences Vinca
Submitting Site:
INIS
Size:
page(s) 13
Announcement Date:
Jul 03, 2006

Citation Formats

Zecevic, V. Report on the state of heavy water system during distillation - Annex 8; Prilog 8 - Izvestaj o stanju teskovodnog sistema u toku destilacije. Serbia and Montenegro: N. p., 1963. Web.
Zecevic, V. Report on the state of heavy water system during distillation - Annex 8; Prilog 8 - Izvestaj o stanju teskovodnog sistema u toku destilacije. Serbia and Montenegro.
Zecevic, V. 1963. "Report on the state of heavy water system during distillation - Annex 8; Prilog 8 - Izvestaj o stanju teskovodnog sistema u toku destilacije." Serbia and Montenegro.
@misc{etde_20743614,
title = {Report on the state of heavy water system during distillation - Annex 8; Prilog 8 - Izvestaj o stanju teskovodnog sistema u toku destilacije}
author = {Zecevic, V}
abstractNote = {Measurements of radiation level were done in 7 points of the heavy water system and distillation system. Measuring results shown in this report show that the radiation intensity was highest on the heat exchangers and lowest on the incoming pipe at the heavy water distillation system. [Serbo-Croat] Merenja intenziteta zracenja vrsena su u 7 tacaka teskovodnog sistema i sistema destilacije. Rezultati merenja prikazani u ovom izvestaju pokazuju da je intenzitet zracenja najveci na toploizmenjivacima, a najmanji na dovodnoj cevi teske vode na destilaciji.}
place = {Serbia and Montenegro}
year = {1963}
month = {Dec}
}